Voltage Distribution of Internal Windings of Pole-Mounted Distribution Transformer by Lightning Surge and Measures for Voltage Reduction

When steep lightning surge enters a pole-mounted distribution transformer, the voltage distribution of the internal windings is unbalanced. It is known that a layer-to-layer short or a turn-to-turn short occurs where the voltage distribution of windings is high. In this paper, the voltage distribution of the windings was measured at the primary and secondary sides of the transformer using a tes...

متن کامل

High frequency input impedance modeling of low-voltage residential installations - influence on lightning overvoltage simulations results

The overvoltage level of a system is strongly dependent on the connected loads and with more precise models, better and more reliable simulation results are obtained. This paper presents the input impedance characteristics, measured over a wide range of frequencies, of various actual low-voltage residential installations. The measured frequency responses were fitted by effective RLC models and ...

متن کامل

Study on Lightning Intruding Overvoltage in Yantan Extension Substation

500kV substation is especially important to the grid of our country, once it encounters lightning damage, the safety and reliability of the whole power system will be directly affected. As lightning intruding waves will cause overvoltage on electric equipments by intruding from the transmission line or straightly stroking the substation, which seriously influences the insulation level of equipm...

متن کامل

Performance of Medium Voltage Overhead Distribution Lines Against Lightning Discharges

The lightning discharges are one of the main causes of interruptions of medium voltage overhead distribution lines, being the reason of great concern for the utility companies. Its destructive effects frequently extends to equipments and connected installations, with the possibility to cause personal injuries and material damages, beyond economic losses, due to out of income and the possibility...