Response of LiF (TLD-700) thermoluminescence detectors to pions and high-energy neutrons
نویسندگان
چکیده
منابع مشابه
Energy response for high-energy neutrons of multi-functional
We have developed a small, light, and multi-functional electronic personal dosimeter (EPD) using four semiconductor radiation detectors for dose monitoring of workers at nuclear power plants and high-energy accelerator facilities. This dosimeter is about 103 x 55 x 15 mm in size and approximately 110 g in weight, and capable of measuring gamma-ray and neutron doses in Hp(10), and beta-ray dose ...
متن کاملthe role of russia in transmission of energy from central asia and caucuses to european union
پس ازفروپاشی شوروی،رشد منابع نفت و گاز، آسیای میانه و قفقاز را در یک بازی ژئوپلتیکی انرژی قرار داده است. با در نظر گرفتن این منابع هیدروکربنی، این منطقه به یک میدانجنگ و رقابت تجاری برای بازی های ژئوپلتیکی قدرت های بزرگ جهانی تبدیل شده است. روسیه منطقه را به عنوان حیات خلوت خود تلقی نموده و علاقمند به حفظ حضورش می باشد تا همانند گذشته گاز طبیعی را به وسیله خط لوله مرکزی دریافت و به عنوان یک واس...
15 صفحه اولRBE-dose relations for neutrons and pions.
From cellular radiosensitivity parameters and theoretical particle-energy spectra in tissue, of the secondary particles from neutron and negative pion irradiations, RBE-Dose relations have been calculated. The theoretical results are compared with clinical and radiobiological data for normal tissue, tumours and cells in culture. Formulae for calculation, cellular parameters and the needed prope...
متن کاملSupralinearity of Peak 5 and Peak 6 in TLD-700
Track theory has been applied to an earlier suggestion, that the supralinearity of TLDs at high gamma-ray doses is due to pre-existing 1-hit and 2-hit trap structures, to calculate high-LET response. Measured 60Co dose responses for peaks 5 and 6 in LiF (TLD700) were decomposed to yield parameters characterizing each peak as a two-component c-hit mixture. One value of “trap radius” was assigned...
متن کاملInvestigation of LiF, Mg and Ti (TLD-100) Reproducibility
LiF, Mg and Ti cubical TLD chips (known as TLD-100) are widely used for dosimetry purposes. The repeatability of TL dosimetry is investigated by exposing them to doses of (81, 162 and 40.5 mGy) with 662keV photons of Cs-137. A group of 40 cubical TLD chips was randomly selected from a batch and the values of Element Correction Coefficient (ECC) were obtained 4 times by irradiating them to doses...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Instruments and Methods
سال: 1980
ISSN: 0029-554X
DOI: 10.1016/0029-554x(80)90246-3