Response functions of a germanium-sodium iodide detector system
نویسندگان
چکیده
منابع مشابه
CMOS Readout System for a Double-sided Germanium Strip Detector
A wide variety of applications require a hard Xray or gamma ray detector which combine both good spatial resolution and energy resolution. Double-sided solid-state strip detectors provide this capability. We report on the development of CMOS electronics designed for photon detection with strip detectors. These electronics include a low noise preamplifier, semi-gaussian shaping amplifier, discri...
متن کاملThe germanium wall of the GEM detector system
A stack of annular detectors made of high-purity germanium was developed. The detectors are position sensitive with radial structures. The first one (“Quirl”) is double-sided position sensitive defining 40 000 pixels, the following three (E1, E2 and E3) have 32 wedges each. The Quirl acts as tracker while the other three act as calorimeter. The stack was successfully operated in meson productio...
متن کاملGamma and X-Ray Detection Introduction
DETECTOR RESOLUTION Resolution is a measure of the width (full width half max) of a single energy peak at a specific energy, either expressed in absolute keV (as with Germanium Detectors), or as a percentage of the energy at that point (Sodium Iodide Detectors). Better (lower FWHM value) resolution enables the system to more clearly separate the peaks within a spectrum. Figure 1.2 shows two spe...
متن کاملGamma and X-Ray Detection Introduction
DETECTOR RESOLUTION Resolution is a measure of the width (full width half max) of a single energy peak at a specific energy, either expressed in absolute keV (as with Germanium Detectors), or as a percentage of the energy at that point (Sodium Iodide Detectors). Better (lower FWHM value) resolution enables the system to more clearly separate the peaks within a spectrum. Figure 1.2 shows two spe...
متن کاملCharacteristics of an Integrated Germanium Detector Based
An integrated gamma ray spectrometer, incorporating a germanium detector with integral mechanical cooling, digital signal processing electronics, MCA, and communications has been developed. It is intended as a modular subsystem for wide application, including use in stationary or mobile systems for the detection of radioactive materials. The requirements for this application are good low and me...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Instruments and Methods
سال: 1967
ISSN: 0029-554X
DOI: 10.1016/0029-554x(67)91332-8