Respiratory system impedance from 4 to 40 Hz in paralyzed intubated infants with respiratory disease.

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Respiratory system impedance from 4 to 40 Hz in paralyzed intubated infants with respiratory disease.

To describe the mechanical characteristics of the respiratory system in intubated neonates with respiratory disease, we measured impedance and resistance in six paralyzed intubated infants with respiratory distress syndrome, three of whom also had pulmonary interstitial emphysema. We subtracted the effects of the endotracheal tube after showing that such subtraction was valid. Oscillatory flow ...

متن کامل

BK Polyomavirus in Respiratory Specimens of Patients with Respiratory Disease

Background and Aims: The role of BK and JC polyomaviruses (BKV and JCV) in the causation of respiratory disease and the natural route of transmission has not well been established. The aim of study was to determine the prevalence of BK and JC viruses in 280 respiratory samples and evaluate their contribution to respiratory disease. Materials and Methods: PCR was used to screen specimens for BK...

متن کامل

Characteristics of heart period variability in intubated very low birth weight infants with respiratory disease.

BACKGROUND Heart period variability provides a measure of balance between the sympathetic nervous system (SNS) and parasympathetic nervous system (PNS). Since the PNS develops during the final weeks of gestation, premature infants have an overriding SNS. Spectral power analysis of heart period variability reveals two main frequency regions, the low frequency region (LF) representing primarily S...

متن کامل

Respiratory system mechanics in sedated, paralyzed, morbidly obese patients.

The effects of inspiratory flow and inflation volume on the mechanical properties of the respiratory system in eight sedated and paralyzed postoperative morbidly obese patients (aged 37.6 +/- 11.8 yr who had never smoked and had normal preoperative seated spirometry) were investigated by using the technique of rapid airway occlusion during constant-flow inflation. With the patients in the supin...

متن کامل

Servocontrolled generator to measure respiratory impedance from 0.25 to 26 Hz in ventilated patients at different PEEP levels.

Assessing respiratory impedance (Zrs) in ventilated patients over a wide frequency band, ranging from breathing rates to typical forced oscillation frequencies, during end-expiratory pauses at different positive end-expiratory pressures (PEEP) is of potential interest to assess a patient's respiratory mechanics. Zrs measurements under these conditions are not possible with the present variants ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Clinical Investigation

سال: 1983

ISSN: 0021-9738

DOI: 10.1172/jci111061