Respiratory pulsations affect fontan connection power loss: using real time velocity mapping to improve the accuracy of computational simulations

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Respiratory pulsations affect fontan connection power loss: using real time velocity mapping to improve the accuracy of computational simulations

Background Total cavopulmonary connection (TCPC) hemodynamics has been hypothesized to be associated with long-term complications in single ventricle heart defect patients. Breath-holding or averaged free-breathing segmented phase contrast magnetic resonance imaging (PC-MRI) has been commonly used for the boundary conditions in numerical simulations to evaluate TCPC hemodynamics. However, the i...

متن کامل

the effects of time planning and task complexity on accuracy of narrative task performance

هدف اصلی این تحقیق بررسی تاثیر برنامه ریزی زمانی، هم چنین افزایش میزان پیچیدگی تکالیف در نظر گرفته شده بصورت همزمان، بر دقت و صحت و پیچیدگی عملکرد نوشتاری زبان آموزان می باشد. بدین منظور، 50 نفر از دانش آموزان دختر در رده ی سنی 16 الی 18 سال به عنوان شرکت کنندگان در این زمینه ی تحقیق در نظر گرفته شدند و به دو گروه آزمایشی و کنترل بصورت اتفاقی تقسیم شدند. اعضای گروه آزمایشی هر دو تکلیف ساده و پی...

Real Time Dynamic Simulation of Power System Using Multiple Microcomputers

Recent developments in the design and manufacture of microcomputers together with improved simulation techniques make it possible to achieve the speed and accuracy required for the dynamic simulation of power systems in real time. This paper presents some experimental results and outlines new ideas on hardware architecture, mathematical algorithms and software development for this purpose. The ...

متن کامل

Real Time Pseudo-Range Correction Predicting by a Hybrid GASVM model in order to Improve RTDGPS Accuracy

Differential base station sometimes is not capable of sending correction information for minutes, due to radio interference or loss of signals. To overcome the degradation caused by the loss of Differential Global Positioning System (DGPS) Pseudo-Range Correction (PRC), predictions of PRC is possible. In this paper, the Support Vector Machine (SVM) and Genetic Algorithms (GAs) will be incorpor...

متن کامل

Impact of respiration on stroke volumes in paediatric controls and Fontan patients assessed by MR real-time phase velocity mapping

Methods Non-electrocardiographic triggered real-time PC-MRI using EPI combined with half-Fourier technique (TR/ TEeff/excitation angle = 12-14 ms/3.3 ms/40°, SENSEfactor = 4, temporal resolution = 24-28 ms) was applied to study respiration-driven SV fluctuations in the ascending aorta (AAo) and both caval veins (SVC, IVC) under natural and forced breathing in 34 healthy children and 10 pediatri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Cardiovascular Magnetic Resonance

سال: 2015

ISSN: 1532-429X

DOI: 10.1186/1532-429x-17-s1-o95