Respiratory impedance in healthy subjects: baseline values and bronchodilator response

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Respiratory impedance in healthy subjects: baseline values and bronchodilator response.

Because of the minimal demand for cooperation by the subject, the forced oscillation technique is increasingly employed in routine lung function testing. However, comprehensive and device-independent values of respiratory impedance at baseline and after bronchodilation have not been established for healthy adults. The aim of this multicentre study was to collect impedance data from 4 to 26 Hz i...

متن کامل

Baseline values of cardiovascular and respiratory parameters predict response to acute hypoxia in young healthy men.

The majority of the available works have studied distinct hypoxic responses of respiratory and cardiovascular systems. This study examines how these systems interact while responding to hypoxia and whether baseline metrics moderate reactions to a hypoxic challenge. Central hemodynamic, aortic wave reflection, and gas exchange parameters were measured in 27 trained young men before and after 10-...

متن کامل

Bronchodilator response in patients with normal baseline spirometry.

BACKGROUND Spirometry before and after bronchodilator is performed to assess air flow-limitation reversibility. In patients with normal baseline spirometry the frequency of a positive bronchodilator response, as defined by American Thoracic Society/European Respiratory Society criteria, has not been described. METHODS We retrospectively analyzed adult patients tested in 2 academic pulmonary ...

متن کامل

Phase Angle Measurement in Healthy Human Subjects through Bio-Impedance Analysis

Objective(s)Bioelectrical impedance is the measure of impedance of the body. Impedance consists of electric resistance and reactance. Phase angle (PA) is the tan value of the ratio of reactance versus electric resistance. PA depends on cell membrane integrity and on body cell mass. There exists a correlation between PA values and body cell mass.The objective of this study was to compare the PA ...

متن کامل

Reference values for respiratory system impedance using impulse oscillometry in healthy preschool children

PURPOSE The normal values for lung resistance and lung capacity of children, as determined by impulse oscillometry (IOS), are different for children of different ethnicities. However, reference values there is no available reference value for Korean preschool children have yet to be determined. The aim of the present study was to determine the normal ranges of IOS parameters in Korean preschool...

متن کامل