Resonant Dephasing in the Electronic Mach-Zehnder Interferometer
نویسندگان
چکیده
منابع مشابه
Resonant dephasing in the electronic Mach-Zehnder interferometer.
We address the recently observed unexpected behavior of Aharonov-Bohm oscillations in the electronic Mach-Zehnder interferometer that was realized experimentally in a quantum Hall system [I. Neder, Phys. Rev. Lett. 96, 016804 (2006)10.1103/PhysRevLett.96.016804]. We argue that the measured lobe structure in the visibility of oscillations and the phase rigidity result from a strong long-range in...
متن کاملNonequilibrium dephasing in an electronic Mach-Zehnder interferometer.
We study nonequilibrium dephasing in an electronic Mach-Zehnder interferometer. We demonstrate that the shot noise at the beam splitter of the interferometer generates an ensemble of nonequilibrium electron density configurations and that electron interactions induce configuration-specific phase shifts of an interfering electron. The resulting dephasing exhibits two characteristic features, a l...
متن کاملInfluence of dephasing on shot noise in an electronic Mach-Zehnder interferometer.
We analyze shot noise under the influence of dephasing in an electronic Mach-Zehnder interferometer, of the type that was realized recently [Nature (London) 422, 415 (2003)]]. Using a model of dephasing by a fluctuating classical field, we show how the usual partition noise expression T(1-T) is modified. We study the dependence on the power spectrum of the field, which is impossible in simpler ...
متن کاملEffects of dephasing on shot-noise in an electronic Mach-Zehnder interferometer
We present a theoretical study of the influence of dephasing on shot noise in an electronic MachZehnder interferometer. In contrast to phenomenological approaches, we employ a microscopic model where dephasing is induced by the fluctuations of a classical potential. This enables us to treat the influence of the environment’s fluctuation spectrum on the shot noise. We compare against the results...
متن کاملMach–Zehnder–Fano interferometer
We introduce a concept of the Mach–Zehnder–Fano interferometer by inserting a cavity exhibiting Fano resonance into a conventional interferometer. By employing the scattering-matrix approach, we demonstrate that the transmission becomes sensitive to a position of the cavity such that an asymmetric structure exhibits a series of narrow resonances with almost perfect reflection. We discuss how to...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Physical Review Letters
سال: 2007
ISSN: 0031-9007,1079-7114
DOI: 10.1103/physrevlett.99.156801