Resolution of Shock-Induced Aortic Regurgitation With an Intraaortic Balloon Pump
نویسندگان
چکیده
منابع مشابه
Resolution of shock-induced aortic regurgitation with an intraaortic balloon pump.
An 80-year-old man was admitted to our hospital with a diagnosis of non–ST-elevation acute coronary syndrome. His past history included severe aortic stenosis and coronary artery disease, for which he had undergone aortic valve replacement with a Björk-Shiley mechanical prosthesis and triple coronary artery bypass with the use of saphenous vein grafts 30 years before. He had been well until 1 y...
متن کاملSuccessful treatment of cardiogenic shock with an intraaortic balloon pump following aluminium phosphide poisoning.
Aluminium phosphide (AlP) is a highly toxic pesticide that inhibits cytochrome oxidase c and causes oxidative stress. Death results from refractory cardiogenic shock due to myocardial dysfunction. There is very little information regarding extracorporeal life support in severe AlP poisoning. Although several therapies are available, none are curative. We report on the use of an intra-aortic bal...
متن کاملParaplegia associated with intraaortic balloon pump counterpulsation.
Two patients developed paraplegia associated with the use of the intraaortic balloon pump. In one patient, transient spinal ischemic episodes ceased after removal of the intraaortic balloon and the second patient apparently sustained spinal cord infarction. Possible etiologic mechanisms include vascular occlusion due to balloon position, arterial spasm, thromboembolic phenomena, hypotension, hy...
متن کاملEfficacy of a new intraaortic propeller pump vs the intraaortic balloon pump: an animal study.
OBJECTIVE To compare the efficacy of a new intraaortic propeller pump (PP) to provide hemodynamic support to the intraaortic balloon pump (IABP) in an acute mitral regurgitation (MR) animal model. BACKGROUND A new intraaortic PP (Reitan catheter pump; Jomed; Helsingborg, Sweden) recently has been introduced. The pump's aim is a reduction in afterload via a deployable propeller that is placed ...
متن کاملPulse oximetry during intraaortic balloon pump application.
BACKGROUND Pulse oximeters are multiple used devices in anaesthesiology and intensive care medicine and must provide reliable data during various conditions of signal interference, including light, motion and reduced perfusion. The aim of this study was to evaluate the reliability of different new-generation pulse oximeters during intraaortic balloon pump (IABP) therapy. METHODS In the experi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Circulation
سال: 2011
ISSN: 0009-7322,1524-4539