Resolution and Enhancement in Nanoantenna-Based Fluorescence Microscopy
نویسندگان
چکیده
منابع مشابه
Nanoantenna array-induced fluorescence enhancement and reduced lifetimes
Enhanced fluorescence is observed from dye molecules interacting with optical nanoantenna arrays. Elliptical gold dimers form individual nanoantennae with tunable plasmon resonances depending upon the geometry of the two particles and the size of the gap between them. A fluorescent dye, Rhodamine 800, is uniformly embedded in a dielectric host that coats the nanoantennae. The nanoantennae act t...
متن کاملExtended resolution fluorescence microscopy.
Fluorescence microscopy is an essential tool of modern biology, but, like all forms of optical imaging, it is subject to physical limits on its resolving power. In recent years, several exciting techniques have been introduced to exceed these limits, including standing wave microscopy, 4Pi confocal microscopy, I5M and structured illumination microscopy. Several such techniques have been definit...
متن کاملResolution enhancement techniques in microscopy
We survey the history of resolution enhancement techniques in microscopy and their impact on current research in biomedicine. Often these techniques are labeled superresolution, or enhanced resolution microscopy, or light-optical nanoscopy. First, we introduce the development of diffraction theory in its relation to enhanced resolution; then we explore the foundations of resolution as expounded...
متن کاملConcepts for nanoscale resolution in fluorescence microscopy.
Spatio-temporal visualization of cellular structures by fluorescence microscopy has become indispensable in biology. However, the resolution of conventional fluorescence microscopy is limited by diffraction to about 180 nm in the focal plane and to about 500 nm along the optic axis. Recently, concepts have emerged that overcome the diffraction resolution barrier fundamentally. Formed on the bas...
متن کاملSubdiffraction resolution in far-field fluorescence microscopy.
We overcame the resolution limit of scanning far-field fluorescence microscopy by disabling the fluorescence from the outer part of the focal spot. Whereas a near-UV pulse generates a diffraction-limited distribution of excited molecules, a spatially offset pulse quenches the excited molecules from the outer part of the focus through stimulated emission. This results in a subdiffraction-sized e...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nano Letters
سال: 2009
ISSN: 1530-6984,1530-6992
DOI: 10.1021/nl902183y