Residual Stress Measurement on a MEMS Structure With High-Spatial Resolution
نویسندگان
چکیده
منابع مشابه
A Study on Alleviating Deformation of MEMS Structure and Prediction of Residual Stress in Surface Micromachining
Recently, the acceptance of micro electromechanical systems (MEMS) technology is growing in various areas such as medical, optical, automobile and telecommunication. In realizing the needs in MEMS, techniques derived from mechanical engineering plays an essential role in the determination of geometric design variables and process parameters, experiments in fabrication and the elastic and plasti...
متن کاملA measurement of Young’s modulus and residual stress in MEMS bridges using a surface profiler
This paper addresses a relatively simple method of measuring Young’s modulus and residual stress in microelectromechanical systems (MEMS) type structures. A surface profilometer is used to measure the deflection of thin film fixed-fixed beams due to the force applied by the profilometer probe. These measurements are analyzed using analytical beam theory. The treatment of end effects and the acc...
متن کاملMEMS Test Structures for Residual Stress Measurements
A set of microstructures for in situ stress measurement is presented, based on a lancet principle having dedicated designs for the amplification of dimensional variation induced by internal stress of the materials. The presented technique has an advantage over the traditional rotating structures and wafer curvature measurements in terms of the simplified readout mechanism. The test structures a...
متن کاملAccurate Model of Capacitance for MEMS Sensors using Corrugated Diaphragm with Residual Stress
In this paper we present a new model for calculating the capacitance of MEMS sensor with corrugated diaphragm. In this work the effect of residual stress is considered on deflection of diaphragm and capacitance of sensor. First, a new analytical analyzes have been carried out to derive mathematic expressions for central deflection of corrugated diaphragm and its relationship with residual stres...
متن کاملMeasurement of Bremsstrahlung Profile with a High - Spatial Resolution on LHD
Measurements of the bremsstrahlung emission profile have been made in order to measure the effective charge (Z.n) profile in Large Helical Device (LHD). The main diagnostic system consists of a 84 optical fiber array, an interference filter and 84 photomultipliers, which gives a spatial resolution of 5 cm at the plasma center. To evaluate the contribution of impurity line radiation, the wavelen...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Microelectromechanical Systems
سال: 2007
ISSN: 1057-7157,1941-0158
DOI: 10.1109/jmems.2006.879701