منابع مشابه
Residual stress in bone structure and tissue of rabbit's tibiofibula.
This paper presents an X-ray diffraction method of measuring the residual stress/strain in bone tissue of rabbit's tibia. To derive the residual stress, bone powder of the diameter less than 40 micrometers was used as a control specimen at non-stressed state. From the X-ray measurements, it was clear that the distribution of residual stress existed in the bone tissue. The tensile residual stres...
متن کاملInducing Residual Stress in Bone Using Abrasive Air-jet Surface Treatment
Based on past research, the growth and repair of bone is a function of physical activity (i.e. stresses) and bone chemistry. As such, the rate of recovery of an individual that has undergone total joint arthroplasty could be influenced by the introduction of changes in bone chemistry and “apparent” stress state in the bone that results from the surgical procedures and/or treatments. This prelim...
متن کاملEffects of the Residual Stress and Bias Voltage on the Phase Diagram and Frequency Response of a Capacitive Micro-Structure
In this paper, static and dynamic behavior of a varactor of a micro-phase shifter under DC, step DC and AC voltages and effects of the residual stress on the phase diagram have been studied. By presenting a mathematical modeling, Galerkin-based step by step linearization method (SSLM) and Galerkin-based reduced order model have been used to solve the governing static and dynamic equations, resp...
متن کاملResidual Stress Variation in Polysilicon Thin Films
This paper compares the use of four mechanical methods for characterization of residual stress variation in low pressure chemical vapor deposited (LPCVD) polysilicon thin films deposited, doped, and annealed under different conditions. Stress was determined using buckling structures, vibrating microstructures, static rotating structures and the wafer curvature method. After deposition of 1.0 μm...
متن کاملResidual Stress, Stress Relief, and Inhomogeneity in Aluminum Plate
Through-thickness residual-stress profiles in rolled 7050-T74 aluminum plate were measured before and after stress relief by stretching (-Tx51). Measurement required adapting the crack compliance method to measure both inplane stress components. Unexpected features in the profiles could be explained by through-thickness yield strength variations caused by crystallographic texture.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: TRENDS IN THE SCIENCES
سال: 2014
ISSN: 1342-3363,1884-7080
DOI: 10.5363/tits.19.4_34