Residual Flux Measurement of Inrush Current of Three Phase Transformer Based on MATLAB
نویسندگان
چکیده
منابع مشابه
A Method for Calculation of the Inrush Current in Single Phase Transformer including the Residual Flux
A field-circuit method for simulation of transients in a single-phase, two-winding transformer has been given. The magnetic field excited by the winding currents has been analyzed, and integral parameters have been determined. Including the equivalent circuit parameters and the magnetic residual flux in the silicon steel core, the developed method has been implemented for the transitional state...
متن کاملMitigation Transformer Inrush Current Using Modified Transient Current Limiter
This study presents a modified transient current limiter (MTCL) for mitigation the inrush current of transformers. The MTCL is based on conventional transient current limiter (TCL), which, its configuration is modified to overcome the TCL drawbacks of operation. The proposed MTCL offers lower power losses and voltage/current THD during normal operation mode. It needs only one limiting reactor i...
متن کاملTransient Transformer Inrush Currents due to Closing Time- and Residual Flux Measurement- Deviations if Controlled Switching is used
During energisation of power transformers, transient inrush currents with peaks up to the short-circuit current may arise. Using controlled switching taking into account the residual flux, the transients can – in theory – be eliminated completely. Real factors such as closing time scatter and residual flux measurement uncertainty have to be considered when checking the suitability of controlled...
متن کاملPower Transformer Modeling for Inrush Current Calculation
The paper documents a new transformer model in ATPDraw called XFMR. This model handles 3-phase transformers with two or three windings. Autotransformers and all Wye and Delta couplings are supported. The model includes an inverse inductance matrix for the leakage description, optional frequency dependent winding resistance, capacitive coupling, and a topologically correct core model (3and 5-leg...
متن کاملTransformer Inrush Current and Related Challenges
Energizing of large power transformers is considered a critical event in the operation of an electric power system. When a transformer is energized by the grid or utility, it takes very high value current known as inrush current, the typical value of this current could be ten times. This inrush causes many problems like mechanical stress on transformer & harmonics injection to generator winding...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: DEStech Transactions on Engineering and Technology Research
سال: 2017
ISSN: 2475-885X
DOI: 10.12783/dtetr/tmcm2017/12605