Research on Mechanism of over Current When Non-contact On-load Tap Changer Regulating Voltage
نویسندگان
چکیده
منابع مشابه
Effect of Solid-State on Load Distribution Transformer Tap-Changer on Power Quality Enhancement
Recently electronic tap-changer has received more attention due to its quick response, better performance and simpler maintenance compared to the mechanical tap-changer. This paper presents the capability of the distribution transformer equipped with an electronic tap-changer for improving power quality. At this end, the analytical computation for determining the compensating limit of electroni...
متن کاملDecentralized tap changer blocking and load shedding against voltage instability: prospective tests on the RTE system
This paper reports on prospective tests of a system protection scheme against long-term voltage instability relying on a set of distributed controllers, each monitoring a transmission voltage, blocking tap changers and shedding loads in a zone. The emergency actions adjust in magnitude and location to the disturbance. Each controller acts in closed-loop, which guarantees robustness. The method ...
متن کاملSolid - State On Load Tap - Changer for Transformer Using Microcontroller
The on-load tap changing (OLTC) regulators have been widely used since the introduction of electrical energy. They ensure a good regulation of the output voltage in presence of large variations of the input voltage with typical response time from several mili-seconds to several seconds. Earlier mechanical type of on load tap changers were into practice. But they had considerable limitations and...
متن کاملImprovement of on-load tap changer performance in voltage regulation of MV distribution systems with DG units using D-STATCOM
This paper presents a new technique for the voltage regulation of a radial medium voltage (MV) distribution grid in presence of distributed generation (DG) units. The proposed technique consists of the coordinated action of on-load tap changer (OLTC) of transformer and reactive power compensation by D-STATCOM. Managing the system voltage using the action of OLTC is one of the most common ways f...
متن کاملFault Diagnosis of On-Load Tap-Changer Based on Variational Mode Decomposition and Relevance Vector Machine
Abstract: In order to improve the intelligent diagnosis level of an on-load tap-changer’s (OLTC) mechanical condition, a feature extraction method based on variational mode decomposition (VMD) and weight divergence was proposed. The harmony search (HS) algorithm was used to optimize the parameter selection of the relevance vector machine (RVM). Firstly, the OLTC vibration signal was decomposed ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Energy Procedia
سال: 2012
ISSN: 1876-6102