Research on air-conditioning usage behaviour in offices with different occupancy
نویسندگان
چکیده
Occupant behaviours in the buildings are not only random and uncertain but also related to each occupant’s habitual preference. This leads performance gap between actual expected energy consumption buildings. Therefore, accurate information modelling with regard occupant behaviour important for reliable simulation energy-saving optimization design. Existing studies on models office space usually focus single-person offices or full-floor buildings, without considering behavioural differences among different occupancy. this study established air-conditioning usage occupancy based questionnaires measured data. The results show that compromise clustering effect will increase of Using as input, compared under standard schedule. difference rate is high 32.19% winter 13.07% whole year. And areas winter, may be bigger.
منابع مشابه
Localized air-conditioning with occupancy control in an open office
Conditioning and ventilating open office spaces requires innovations as new buildings aim to be more intelligent, energy efficient and healthy. This paper explores the possibility of using a localized airflow to divide an open cubicle office into zones without partition walls. Computational fluid dynamics (CFD) model was used to simulate localized airflow in a cubicle office and both the energy...
متن کاملThermal Comfort in Offices – Natural Ventilation vs. Air Conditioning
Based on both subjective and objective data, a study was carried out in order to identify differences in the perception of thermal comfort of office workers in naturally ventilated and air-conditioned buildings. The analysis of the interviews shows that occupants of naturally ventilated office buildings are significantly more satisfied with their thermal environment than occupants in air-condit...
متن کاملFully Fresh Air Air-conditioning System Equipped with Double Heat Pipe Based Heat Recovery Technology
The using of double heat pipe based heat exchanger (HPHX) in a conventional fully fresh air air-conditioning (AC) system was examined in the present study. The fabricated HPHXs were tested under the actual conditions and the measured data were used to study the performance of the existing AC system (System A) and AC system equipped with the double HPHX (System B) for a yearly operation through ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: E3S web of conferences
سال: 2022
ISSN: ['2555-0403', '2267-1242']
DOI: https://doi.org/10.1051/e3sconf/202235601041