Research and implementation of single point focusing system based on planar array ultrasonic transducer
نویسندگان
چکیده
منابع مشابه
Phased array ultrasonic imaging using an improved beamforming based total focusing method for non destructive test
One of the novel ultrasonic phased array based scanning methods for ultrasonic imaging in non-destructive test is total focusing method (TFM). This method employs maximum available information of the phased array elements and leads to an improved defect detection accuracy compared to conventional scanning methods. Despite its high detection accuracy, TFM behaves weak in distinguishing the real ...
متن کاملSingle Array and Bound Method (RESEARCH NOTE).
One of the major disadvantages of using Branch and Bound algorithm to solve permutation bases problems by computer is the size of main memory required. The single Array Branch and Bound (SABB) method introduction here aims to overcome this deficiency, using only N memory locations as a vector of size N, and a single cell C with N bits.
متن کاملPhased array ultrasonic imaging using an improved beamforming based total focusing method for non destructive test
One of the novel ultrasonic phased array based scanning methods for ultrasonic imaging in non-destructive test is total focusing method (TFM). This method employs maximum available information of the phased array elements and leads to an improved defect detection accuracy compared to conventional scanning methods. Despite its high detection accuracy, TFM behaves weak in distinguishing the real ...
متن کاملThe study of phased-ultrasonic receiving-planar array transducer for PD location in power transformer
Partial discharge (PD) is the main cause of electric equipment degradation. PD location can provide the scientific direction and analysis for equipment condition monitoring. The phased-ultrasonic receiving-planar array transducer for PD location in transformer is studied in this paper. The operation environment and material properties of transducer are analyzed. The center frequency of transduc...
متن کاملDesign and Fabrication of a Longitudinal-Torsional Ultrasonic Transducer
A hybrid longitudinal-torsional ultrasonic transducer is designed and fabricated in this research. The design of the transducer was performed using the FE method with ABAQUS software, with the aim of combining the longitudinal and torsional vibration modes. The transducer horn is then fabricated using a 4-axis milling machine. The PZT stacks are employed in order to excite the transducer. The t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Physics: Conference Series
سال: 2020
ISSN: 1742-6588,1742-6596
DOI: 10.1088/1742-6596/1549/3/032061