Research and Development of XLPE Insulated DC Cable

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Long-life Xlpe Insulated Power Cable

Crosslinked polyethylene (XLPE) has become the globally preferred insulation for power cables, both for distribution and transmission system applications. This insulation system provides cost efficiency in operation and procurement, as well as lower environmental and maintenance requirements when compared to older impregnated paper systems. The purpose of this paper is to outline some of the de...

متن کامل

The Influence of Material Modification and Residues on Space Charge Accumulation in XLPE for DC Cable Application

Effects of cross-linking by-products (residues) of polyethylene on space charge accumulation and decay are investigated in the paper using the pulsed electro-acoustic technique. Space charge profiles have shown a great variation both in the charge initiation over the voltage ramping up process and later on long term stressing and decay (volts off) among the samples subjected to different condit...

متن کامل

The Conduction Characteristics of Electrical Trees in XLPE Cable Insulation

Depending on the morphology of the material and applied voltage frequency, three kinds of electrical trees can exist in cross-linked polyethylene (XLPE) cable insulation, which are conducting, non-conducting, and mixed trees with different growth mechanisms. It is suggested that when the needle is inserted into large spherulites, conducting trees will form in those spherulites; when it is inser...

متن کامل

A Methodology for the Assessment of Hvdc-xlpe Cable Insulation

The purpose of this work is to present and to discuss a methodology for the assessment of materials intended to HVDC-XLPE cables, particularly as regards the evaluation of the effects of material formulation on space charge accumulation within the insulation. Sample design, testing method and protocol and criteria used for the material evaluation are specifically considered. It will be shown th...

متن کامل

Research on Partial Discharge Localization in XLPE Cable Accessories Using Multi-Sensor Joint Detection Technology

A multi-sensor joint detection technology was proposed based on the theory of the high frequency current transformer (HFCT) method, Ultra-high frequency (UHF) method and acoustic emission (AE) method. An experimental partial discharge (PD) testing was applied on XLPE cable with artificial defect signals. The experimental results show that the multi-sensor joint detection technology will help to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEJ Transactions on Power and Energy

سال: 1992

ISSN: 0385-4213,1348-8147

DOI: 10.1541/ieejpes1990.112.10_905