Requirements for Preventing Trouble Originating with Retainer of Magnetic Attachments
نویسندگان
چکیده
منابع مشابه
Magnetic Attachments
This study investigated the effect of heat history on the eorrosion of keepers used for dental magnetic attachments. Ferritic stainless steels of SUS 444 and 447Jl were prepared with heat treatments in the temperature range of 550-850°C for 1-5 hours. The stainless steels were electrochemically and metallurgically examined by anodic polarization curves in a O.9% NaCl solution and by microstruct...
متن کاملIdentifying Requirements of a Self-care System on Smartphones for Preventing Coronavirus Disease 2019 (COVID-19)
Background: Smartphone applications play a pivotal role in management, providing care and preventing infectious diseases. It also has the potential impact on supportive and self-care. This study aimed to identify the requirements for a smartphones self-care system to prevent corona-virus (COVID-19). Materials & Methods: This was a descriptive study performed in two main stages in 2020. At the ...
متن کاملTrouble with Overconfidence 1 Running head: TROUBLE WITH OVERCONFIDENCE The Trouble with Overconfidence
This paper presents a reconciliation of the three distinct ways in which the research literature has defined overconfidence: (1) overestimation of one’s actual performance, (2) overplacement of one’s performance relative to others, and (3) excessive precision in one’s beliefs. Experimental evidence shows that reversals of the first two (apparent underconfidence), when they occur, tend to be on ...
متن کاملEffect of Heat History on the Corrosion of Magnetic Attachments
This study investigated the effect of heat history on the corrosion of keepers used for dental magnetic attachments. Ferritic stainless steels of SUS 444 and 447J1 were prepared with heat treatments in the temperature range of 550-850t for 1-5 hours. The stainless steels were electrochemically and metallurgically examined by anodic polarization curves in a 0.9% NaC1 solution and by microstructu...
متن کاملApplications of Magnetic Attachments in Dental Prosthesis Technology
SORIN POROJAN1, LILIANA POROJAN2* 1 V. Babes University of Medicine and Pharmacy Timisoara, Faculty of Dentistry, Department of Oral Rehabilitation, Specialization Dental Technology, 9 Revolutiei 1989 Blv, Timisoara, Romania 2 Faculty of Dentistry, V. Babes University of Medicine and Pharmacy Timisoara, Department of Prostheses Technology, Specialization Dental Technology, 9 Revolutiei 1989 Blv...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nihon Hotetsu Shika Gakkai Zasshi
سال: 2004
ISSN: 1883-177X,0389-5386
DOI: 10.2186/jjps.48.30