REQUIRED BRACING STIFFNESS TO GIVE THE SPECIFIED EFFECTIVE LENGTH : In symmetrical braced frames
نویسندگان
چکیده
منابع مشابه
Column Effective Length Factor in Khorjini Frames
This paper discusses the effective length factor of columns in Khorjini frames. In order to find this factor, a proper approximated method is proposed. In addition, accurate analysis is performed and the results are compared with those from the proposed technique. The comparison demonstrates the accuracy of presented FORMULATIONS. The proposed method is similar to Julian and Lawrence's, which i...
متن کاملColumn Effective Length Factor in Khorjini Frames
This paper discusses the effective length factor of columns in Khorjini frames. In order to find this factor, a proper approximated method is proposed. In addition, accurate analysis is performed and the results are compared with those from the proposed technique. The comparison demonstrates the accuracy of presented FORMULATIONS. The proposed method is similar to Julian and Lawrences, which is...
متن کاملSeismic Response of Braced Steel Frames with Shape Memory Alloy and Mega Bracing Systems
Steel bracing members are widely used in steel structures to reduce lateral displacement and dissipate energy during earthquake motions. Concentric steel bracing provide an excellent approach for strengthening and stiffening steel buildings. Using these braces the designer can hardly adjust the stiffness together with ductility as needed because of buckling of braces in compression. In this stu...
متن کاملNumerical study on the behavior of link-to-column connections in eccentrically braced frames
Geometry of eccentrically braced frames (EBFs) in some cases causes the connection of link beam to the column. The details of such conditions should be studied carefully due to the full plastic rotation in the link beam. In this research, the behavior of link-to-column connection is modeled and the failure modes are considered. Based on the previous researches shear link can exhibit better beha...
متن کاملoptimization of the steel frames bracing template
the most conventional method for lateral bracing of steel frames is using diagonal and x steel braces. in conventional method, braces of frame emplace in one bay or more, relative to structural requirement, from first to last story without displace the braces emplacement on height as columnar form. this pattern is a preliminary and simplest bracing template that the generally codes present base...