Reproducibility of strain and twist measurements calculated using CSPAMM tagging
نویسندگان
چکیده
منابع مشابه
Reproducibility of strain and twist measurements calculated using CSPAMM tagging
Methods 12 healthy volunteers (6 males, mean age 33±7 years) underwent CMR studies on a 1.5T system (Intera CV, Philips Healthcare, The Netherlands). Tagged CMR images were acquired at the apex, mid-ventricle and base with a CSPAMM pulse sequence (field of view: 300mm, matrix 128 x 128, slice thickness 10mm, tag separation 8mm, 18 phases, typical TR/TE 30ms/6ms, flip angle 25 degrees). In 6 vol...
متن کاملAssessment of Reproducibility of Geometric Distortion in MRI using Phantom Measurements
Introduction: Image distortion is one of the major problems of magnetic resonance imaging (MRI) for use in 3DMRI, velocity MRI, FMRI and radiotherapy treatment planning (RTTP). It is widely known that the most obvious effect of the inhomogenity of the magnetic fields and the nonlinearity of the gradient is the Geometric Distortion of MR tomograms. In this study, the...
متن کاملMeasurements of changes in left ventricular volume, strain, and twist during isovolumic relaxation using MRI.
Left ventricular (LV) active relaxation begins before aortic valve closure and is largely completed during isovolumic relaxation (IVR), before mitral valve opening. During IVR, despite closed mitral and aortic valves, indirect assessments of LV volume have suggested volume increases during this period. The aim of this study is to measure LV volume throughout IVR and to determine the sources of ...
متن کامل3D Whole Heart CSPAMM tagging in a single breath hold using k-t-PCA
Introduction Myocardial tagging techniques [1, 2] have shown great promise in assessing local wall motion abnormalities. Recent work has indicated the value of the method in stratifying patients for cardiac resynchronization therapy [3]. Three-dimensional data acquisition is a prerequisite for a comprehensive analysis of cardiac motion. The combination of reduced field-of-view and line tag prep...
متن کاملInter-study reproducibility of circumferential strain and strain rates at 1.5T and 3T: a comparison of tagging and feature tracking
Background Feature Tracking (FT) is a relatively new technique for measuring strain on cardiac magnetic resonance imaging (CMR), that has been shown to have reasonable interstudy reproducibility (Coefficient of variation (CoV) ~20%) in healthy volunteers. The inter-study reproducibility of FT has not yet been reported in any patient groups, nor compared to that of MRI tagging. We sought to dete...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Cardiovascular Magnetic Resonance
سال: 2011
ISSN: 1532-429X