Reproducibility of linear cardiac output measurement by Doppler ultrasound alone.

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reproducibility of linear cardiac output measurement by Doppler ultrasound alone.

Inclusion of a pig aorta in an artificial circulation with pulsed blood flow allowed correlation of minute distance, measured in the aorta by Doppler ultrasound, and absolute blood flow, measured by timed blood-volume collection. The correlation coefficient was 0.99 with a standard error of prediction that was 5.4% of the minute distance predicted at a standard flow rate of 5 litres per minute....

متن کامل

Reproducibility of measurements of cardiac output in newborn infants by Doppler ultrasound.

Interobserver reproducibility in deriving cardiac output by measuring aortic blood flow velocity and diameter with imaging and Doppler ultrasound was investigated in 20 healthy infants born at full term. Aortic diameter was measured in three ways. Mean blood flow velocity was measured at three sites with both continuous wave and pulsed Doppler. Two observers carried out each study independently...

متن کامل

Reproducibility of cardiac output measurement by cross sectional and Doppler echocardiography.

The variability of Doppler echocardiographic estimation of cardiac output at the aortic orifice was investigated in eight healthy subjects. Cross sectional echocardiograms of the aortic orifice and aortic Doppler velocities were recorded and measured by four echocardiographers. Between subject variability was significantly larger than within subject variability for all variables. Variability ow...

متن کامل

Simultaneous measurement of cardiac output by thermodilution, thoracic electrical bioimpedance and Doppler ultrasound.

To evaluate the accuracy of two non-invasive techniques for cardiac output (CO) measurement, we have measured CO simultaneously by thoracic electrical bioimpedance (TEB), pulsed Doppler ultrasound (DU) and standard thermodilution methods (TD) under different clinical conditions. Measurements were made in 10 patients: (I) during steady state anaesthesia with controlled IPPV ventilation (n = 131)...

متن کامل

Determination of cardiac output by Doppler echocardiography.

Cardiac output determined by Doppler echocardiography was compared with that determined by thermodilution at rest and during dobutamine infusion in 10 patients (group A) and by the Fick method at rest in 11 patients (group B). All patients had angina pectoris without valvular heart disease. Maximum spatial blood velocity and cross sectional aortic area were estimated by the Doppler technique an...

متن کامل