Reproducibility of glucose measurements using the glucose sensor.

OBJECTIVE Recent studies have confirmed that improved glycemic control decreases the risk of diabetic complications in type 1 and type 2 diabetic patients. The Minimed glucose sensor allows continuous 72-h glucose monitoring and represents a potentially important tool to improve diabetes management. Its use is currently limited to the health care team. Our aim was to evaluate the reproducibilit...

متن کامل

A Mems Affinity Glucose Sensor Using Permittivity Measurements

We present a MEMS affinity glucose sensor using permittivity measurements. This device employs a biocompatible glucose-specific polymer as the sensing solution. By introducing the polymer solution between two electrodes, the permittivity of the polymer solution can be measured from the capacitance changes induced by glucose binding. We characterize the frequency-dependent complex permittivity a...

متن کامل

development of different optical methods for determination of glucose using cadmium telluride quantum dots and silver nanoparticles

a simple, rapid and low-cost scanner spectroscopy method for the glucose determination by utilizing glucose oxidase and cdte/tga quantum dots as chromoionophore has been described. the detection was based on the combination of the glucose enzymatic reaction and the quenching effect of h2o2 on the cdte quantum dots (qds) photoluminescence.in this study glucose was determined by utilizing glucose...

A Comparative Study of Blood Glucose Measurements Using Glucometer Readings and the Standard Method in the Diagnosis of Neonatal Hypoglycemia

Background: Hypoglycemia is one of the most common neonatal disorders, associated with severe complications. There has been a great deal of controversy regarding the definition and screening of hypoglycemia. Therefore, in this study, we aimed to determine a cut-off value for blood glucose level in glucometer readings. Methods: This cross-sectional study was conducted on 238 newborns at risk of ...

متن کامل

A fiber optic sensor for measuring glucose in aqueous solutions

In this paper, the set-up of a multi-mode fiber optic sensor for measuring glucose in aqueous solutions is investigated and evaluated. The basis of this sensor is based on the Fresnel Reflection. In this setup, a helium-neon laser is used as a light source, a fiber optic probe, photocell as detector and a digital multimeter. The statistical analysis of the recorded data shows a highly linear be...