Reproducibility of 24-h ambulatory blood pressure and measures of autonomic function
نویسندگان
چکیده
منابع مشابه
Ambulatory blood pressure recordings. Reproducibility and unpredictability.
The accuracy of blood pressure readings taken by the portable semiautomatic blood pressure recorder Remler M 2000 was investigated in 101 unselected, untreated volunteers. On the average, pressures recorded during usual daily activities were lower by approximately 10 mm Hg than pressures measured in the office. However, individual ambulatory pressures could not be predicted from office readings...
متن کاملFactors Affecting Ambulatory Blood Pressure Reproducibility
To assess the reproducibility of ambulatory blood pressure, we recorded 24-hour blood pressure twice 3 months apart in 508 hypertensive subjects participating in the HARVEST trial using a noninvasive technique. Blood pressure was measured every 10 minutes during the daytime and 30 minutes during the nighttime. Reproducibility was better for ambulatory than for office blood pressure. It was grea...
متن کاملIs "usual" blood pressure a proxy for 24-h ambulatory blood pressure in predicting cardiovascular outcomes?
BACKGROUND The 24-h ambulatory blood pressure (ABP) is a stronger predictor of cardiovascular disease than conventional blood pressure (CBP), but it remains unclear how it compares with "usual" blood pressure (UBP), estimated after CBP has been corrected for regression dilution bias (RDB). METHODS We compared the associations of cardiovascular mortality (n = 50), cardiovascular events (n = 10...
متن کاملComparison of wrist-type and arm-type 24-h blood pressure monitoring devices for ambulatory use.
OBJECTIVE(S) We compared a convenient, cuffless, wrist-type ambulatory blood pressure monitoring (ABPM) device (BPro) and a standard arm-type ABPM monitor under ambulatory conditions. METHODS Fifty normotensive and prehypertensive volunteers who had no interarm differences in BP were enrolled. The wrist and arm monitors were attached to the left wrist and the right arm, respectively, and prov...
متن کاملEfficacy of Low-Dose Chlorthalidone and Hydrochlorothiazide as Assessed by 24-h Ambulatory Blood Pressure Monitoring.
BACKGROUND Thiazide and thiazide-like diuretic agents are being increasingly used at lower doses. Hydrochlorothiazide (HCTZ) in the 12.5-mg dose remains the most commonly prescribed antihypertensive agent in the United States. OBJECTIVES This study compared chlorthalidone, 6.25 mg daily, with HCTZ, 12.5 mg daily, by 24-h ambulatory blood pressure (ABP) monitoring and evaluated efficacy. Becau...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Blood Pressure Monitoring
سال: 2017
ISSN: 1359-5237
DOI: 10.1097/mbp.0000000000000241