Reproducibility of 18F-FDG microPET Studies in Mouse Tumor Xenografts

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tumor volume in subcutaneous mouse xenografts measured by microCT is more accurate and reproducible than determined by 18F-FDG-microPET or external caliper

BACKGROUND In animal studies tumor size is used to assess responses to anticancer therapy. Current standard for volumetric measurement of xenografted tumors is by external caliper, a method often affected by error. The aim of the present study was to evaluate if microCT gives more accurate and reproducible measures of tumor size in mice compared with caliper measurements. Furthermore, we evalua...

متن کامل

Monitoring response to gefitinib in nude mouse tumor xenografts by 18 F-FDG microPET-CT: correlation between 18 F-FDG uptake and pathological response

BACKGROUND The purpose of this study is to investigate whether (18)F-fluorodeoxyglucose (FDG) micro-positron emission tomography-computed tomography (microPET-CT) can be used to monitor a metabolic response to gefitinib in nude mouse tumor xenografts. METHODS Sixteen nude mice were implanted with human A431 epidermoid carcinoma cells and ten with human A549 lung adenocarcinoma cells, and the ...

متن کامل

18F-FDG and 18F-FLT-PET Imaging for Monitoring Everolimus Effect on Tumor-Growth in Neuroendocrine Tumors: Studies in Human Tumor Xenografts in Mice

INTRODUCTION The mTOR inhibitor everolimus has shown promising results in some but not all neuroendocrine tumors. Therefore, early assessment of treatment response would be beneficial. In this study, we investigated the in vivo and in vitro treatment effect of everolimus in neuroendocrine tumors and evaluated the performance of 18F-FDG and the proliferation tracer 18F-FLT for treatment response...

متن کامل

13C Tracer Studies of Metabolism in Mouse Tumor Xenografts.

Mice are widely used for human tumor xenograft studies of cancer development and drug efficacy and toxicity. Stable isotope tracing coupled with metabolomic analysis is an emerging approach for assaying metabolic network activity. In mouse models there are several routes of tracer introduction, which have particular advantages and disadvantages that depend on the model and the questions address...

متن کامل

microPET of Tumor Integrin avb3 Expression Using 18F-Labeled PEGylated Tetrameric RGD Peptide (18F-FPRGD4)

In vivo imaging of avb3 expression has important diagnostic and therapeutic applications. Multimeric cyclic RGD peptides are capable of improving the integrin avb3–binding affinity due to the polyvalency effect. Here we report an example of 18F-labeled tetrameric RGD peptide for PET of avb3 expression in both xenograft and spontaneous tumor models. Methods: The tetrameric RGD peptide EfE[c(RGDy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Nuclear Medicine

سال: 2007

ISSN: 0161-5505

DOI: 10.2967/jnumed.106.036608