Report of AAPM Task Group 162: Software for planar image quality metrology
نویسندگان
چکیده
منابع مشابه
AAPM and GEC-ESTRO guidelines for image-guided robotic brachytherapy: report of Task Group 192.
In the last decade, there have been significant developments into integration of robots and automation tools with brachytherapy delivery systems. These systems aim to improve the current paradigm by executing higher precision and accuracy in seed placement, improving calculation of optimal seed locations, minimizing surgical trauma, and reducing radiation exposure to medical staff. Most of the ...
متن کاملUpdate of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations.
Since publication of the American Association of Physicists in Medicine (AAPM) Task Group No. 43 Report in 1995 (TG-43), both the utilization of permanent source implantation and the number of low-energy interstitial brachytherapy source models commercially available have dramatically increased. In addition, the National Institute of Standards and Technology has introduced a new primary standar...
متن کاملThe management of imaging dose during image-guided radiotherapy: report of the AAPM Task Group 75.
Radiographic image guidance has emerged as the new paradigm for patient positioning, target localization, and external beam alignment in radiotherapy. Although widely varied in modality and method, all radiographic guidance techniques have one thing in common--they can give a significant radiation dose to the patient. As with all medical uses of ionizing radiation, the general view is that this...
متن کاملOngoing quality control in digital radiography: Report of AAPM Imaging Physics Committee Task Group 151.
Quality control (QC) in medical imaging is an ongoing process and not just a series of infrequent evaluations of medical imaging equipment. The QC process involves designing and implementing a QC program, collecting and analyzing data, investigating results that are outside the acceptance levels for the QC program, and taking corrective action to bring these results back to an acceptable level....
متن کاملQuality assurance of U.S.-guided external beam radiotherapy for prostate cancer: report of AAPM Task Group 154.
Task Group 154 (TG154) of the American Association of Physicists in Medicine (AAPM) was created to produce a guidance document for clinical medical physicists describing recommended quality assurance (QA) procedures for ultrasound (U.S.)-guided external beam radiotherapy localization. This report describes the relevant literature, state of the art, and briefly summarizes U.S. imaging physics. S...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Medical Physics
سال: 2018
ISSN: 0094-2405
DOI: 10.1002/mp.12718