Replacement of aortic valve flaps with an autopericardium using the S. Ozaki technique
نویسندگان
چکیده
Classical aortic valve replacement is often fraught with negative outcomes for patients. When replacing the a mechanical prosthesis, patient associated life use of indirect anticoagulants, which leads to hemorrhagic and thrombotic complications. In case biological fairly frequent complication early calcification and, consequently, high frequency dysfunctions prosthesis. addition, prosthetics heart valves are quite expensive, creates serious economic load on healthcare institution. But in last decade, technique neocuspidization autopericardial flaps has been introduced into wide cardiac surgical practice, clear alternative valves.
منابع مشابه
Aortic Valve replacement with Reduction Aortoplasty with Mesh Prosthesis in 75 years old with Sever aortic Regurgitation with Aortic Aneurysm
Although classic and standard procedure for patients with ascending Aorta aneurysm with Sever aortic Regurgitation is Bentall surgery but in some selected cases this complex surgery was not performed with different reason like advanced age and coexisting comorbidity involving renal and hepatic and lung Function. In our cases 75 years old man with chronic renal failure ( Cr= 3.2 ) who was known ...
متن کاملAortic Valve Replacement Using Continuous Suture Technique in Patients with Aortic Valve Disease
BACKGROUND The continuous suture (CS) technique has several advantages as a method for simple, fast, and secure aortic valve replacement (AVR). We used a simple CS technique without the use of a pledget for AVR and evaluated the surgical outcomes. MATERIALS AND METHODS Between October 2007 and 2012, 123 patients with aortic valve disease underwent AVR alone (n=28) or with other concomitant ca...
متن کاملTranscatheter Aortic Valve Replacement: A Review Article
Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...
متن کاملContinuous suture technique in aortic valve replacement
Methods Between February 2001 and October 2011, a total number of 443 patients with aortic valve stenosis underwent aortic valve replacement. It was isolated in 217 patients (group A), combined with coronary vascularisation in 137 cases (group B) and with other concomitant cardiac procedures in 89 cases (group C). In all groups continuous suture technique was used. The most of coronary anastomo...
متن کاملContinuous-suture technique in aortic valve replacement.
From April 2000 to April 2003 total 103 patients underwent aortic valve replacement and some concomitant cardiac procedures including mitral valve replacement in our hospital. According to the suture technique used in aortic valve replacement, the patients were divided into two groups: group A, 42 patients, the continuous suture technique with some modifications was used; group B, 61 patients, ...