Repeated Hemorrhage after Repair of Orbital Floor Fracture with a Silicone Implant
A 16-year-old girl was accidentally kicked in her right eye by her cheerleading teammate in an exercise. Upward gaze ability of her right eye was severely impaired and computed tomography (CT) showed a trapdoor fracture of the right orbital floor. After surgical exploration, a silicone implant was inserted. No bleeding was confirmed at this time. The next day, CT detected a hematoma on the righ...
متن کاملEndoscopic endonasal repair of orbital floor fracture.
BACKGROUND High-resolution endoscopes and the advent of endoscopic instruments for sinus surgery provide surgeons with excellent endonasal visualization and access to the orbital walls. OBJECTIVE To demonstrate repair of orbital floor blowout fractures through an intranasal endoscopic approach that allows repair of the orbital floor fracture and elevation of the orbital content using a balloo...
متن کاملNontraumatic orbital floor fracture after nose blowing
A 40-year-old woman with no history of trauma or prior surgery presented to the emergency department with headache and left eye pain after nose blowing. Noncontrast maxillofacial computed tomography examination revealed an orbital floor fracture that ultimately required surgical repair. There are nontraumatic causes of orbital blowout fractures, and imaging should be obtained irrespective of tr...
متن کاملLate Complication of a Silicone Implant Thirty Years after Orbital Fracture Reconstruction
Alloplastic materials used for orbital fracture reconstruction can induce complications, such as infection, migration, extrusion, intraorbital hemorrhage, and residual diplopia. Silicone is one of the alloplastic materials that has been widely used for decades. The author reports a rare case of spontaneous extrusion of a silicone implant that was used for orbital fracture reconstruction 30 year...
متن کاملTransantral Orbital Floor Fracture Repair Using a Folded Silastic Tube
OBJECTIVES The purpose of this study was to evaluate the advantages and limitations of using a silicon tube to support the fractured orbital floor by a transantral approach. METHODS A retrospective study was conducted from January 2000 to December. 2011 in 51 patients with pure orbital floor fractures. The patients underwent reduction surgery via a transantral approach for inserting a folded ...