Repeatability and Agreement of Central Corneal Thickness and Keratometry Measurements between Four Different Devices
Background. To estimate repeatability and comparability of central corneal thickness (CCT) and keratometry measurements obtained by four different devices in healthy eyes. Methods. Fifty-five healthy eyes from 55 volunteers were enrolled in this study. CCT (IOLMaster 700, Pentacam HR, and Cirrus HD-OCT) and keratometry readings (IOLMaster 700, Pentacam HR, and iDesign) were measured. For statis...
متن کاملComparison of central corneal thickness with four noncontact devices: An agreement analysis of swept-source technology
PURPOSE The purpose of this study was to compare the central corneal thickness (CCT) measurements of four noncontact devices in healthy eyes. MATERIALS AND METHODS In a sample of 45 healthy controls, CCT was measured using an optical biometer (IOLMaster 700) based on swept-source optical coherence tomography (SS-OCT), high-resolution rotating Scheimpflug camera system (Pentacam HR), spectral-...
متن کاملAgreement of Central Corneal Thickness Measurements Using two Different Ultra Sound Techniques
Purpose: To compare the Central Corneal Thickness (CCT) measurements obtained by Ultrasound Pachymeter (USP) & Ultrasound Biomicroscope (UBM). Methods: The study CCT measurements of 60 eyes was measured using first with UBM followed by USP. Results were compared statistically using Bland –Altman plots & Deming’s regression analysis Results: Scatter plot analysis showed that for the same value o...
متن کاملCentral corneal thickness measurements with different imaging devices and ultrasound pachymetry.
PURPOSE The aim of this study was to compare 4 methods of central corneal thickness (CCT) measurements in terms of their agreement, repeatability, and measurement time. METHODS CCT was measured in 184 eyes of 92 healthy subjects by the same examiner. The methods used were as follows: noncontact specular microscopy (SM; Topcon SP-3000P; Topcon Corporation, Tokyo, Japan), Pentacam rotating Sche...
متن کاملCentral corneal thickness measurement with different devices in keratoconic patients
We read with great interest the article by Aghazadeh Amiri et al. concerning the corneal thickness (CT) measurements with Scheimpflug and slit scanning imaging techniques in keratoconus (KC). We would like to congratulate with the authors for their very interesting paper because it is well known that the measurement of CT is involved in the reliability of intraocular pressure measurements, both...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Ophthalmology
سال: 2017
ISSN: 2090-004X,2090-0058
DOI: 10.1155/2017/6181405