Reoperation for Starr-Edwards Ball Valve Insufficiency 21 Years after Replacement.

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reoperation for a patient 25 years after a Starr-Edwards ball mitral valve was installed.

A 45-year-old female suffered from increasing dyspnea during exercise and edema of lower extremities from January 2000. She had undergone mitral valve replacement with Starr-Edwards ball prosthesis (model 6320) due to mitral valve regurgitation 25 years ago. The cardiac catheterization and echocardiography documented mitral, aortic and tricuspid valves regurgitation grade III. Left ventricular ...

متن کامل

Prophylactic reoperation after mitral valve replacement with the Starr-Edwards ball valve: a report of four cases.

PURPOSE The Starr-Edwards ball valve was first applied clinically in 1960. In our hospital, this valve has been used since 1963, and some patients have been followed up for 30 years or more. Based on our experience, therapeutic strategies included revalve replacement as a preventive procedure in the absence of valve-related complications. In this study, we investigated whether prophylactic reop...

متن کامل

Replacement of an aortic Starr-Edwards ball valve prosthesis 28 years after implantation.

A 53-year-old woman who had undergone aortic valve replacement with a Starr-Edwards (S-E) valve (Model 1260) and open mitral commissurotomy 28 years previously was hospitalized with cardiac failure. Echocardiography showed mitral stenosis, mitral regurgitation, and a normally functioning S-E prosthesis. At reoperation, the mitral and aortic valves were replaced with St Jude bileaflet mechanical...

متن کامل

Bentall procedure 39 years after implantation of a Starr-Edwards Aortic Caged- Ball-Valve Prosthesis

We report a case of a male patient who received an implantation of a Starr-Edwards-caged-ball-valve-prosthesis in 1967. The surgery and postoperative course were without complications and the patient recovered well after the operation. For the next four decades, the patient remained asymptomatic--no restrictions on his lifestyle and without any complications. In 2006, 39 years after the initial...

متن کامل

Valve dysfunction of the cloth-covered Starr-Edwards ball valve.

BACKGROUND Between June 1968 and March 1977, Starr-Edwards cloth-covered ball valves were used for valve replacement on a routine basis. METHODS AND RESULTS Among the 66 operative survivors who underwent an isolated aortic or mitral valve replacement, 20 patients required reoperation 22 times because of valve dysfunction, thromboembolic complication, paravalvular leakage, hemolytic anemia, an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Japanese Journal of Cardiovascular Surgery

سال: 1995

ISSN: 1883-4108,0285-1474

DOI: 10.4326/jjcvs.24.190