Renal Artery Stenting Following Unsuccessful Balloon Angioplasty
نویسندگان
چکیده
منابع مشابه
Renal artery stenting following unsuccessful balloon angioplasty.
1. DeMaria AN. Editors page: international cardiology. J Am Coll Cardiol 2005;46:1580–1. 2. Cheng TO. The current state of cardiology in China. Int J Cardiol 2004;96:425–39. 3. Cheng TO. Metabolic syndrome in China. Circulation 2004;109:e180. 4. Cheng TO. The metabolic syndrome, formerly called metabolic ‘syndrome X.’ Am J Cardiol 2004;94:148–9. 5. Cheng TO. Obesity is the newest health risk in...
متن کاملCarotid artery balloon angioplasty and stenting (CABAS): a neuroradiologic perspective.
Stroke is the third leading cause of death in the United States, with at least half a million strokes newly diagnosed per year. Most are noncardiogenic, and the majority of those are related to carotid artery atherosclerosis. The cost of treating stroke totals more than $30 billion a year, which does not include the emotional and social costs involved (1). There are effective treatments for car...
متن کاملCase Against Angioplasty and Stenting of Atherosclerotic Renal Artery Stenosis
Atherosclerotic renal artery stenosis (RAS) is a relatively common problem, estimated to affect between 1% and 5% of patients with hypertension.1,2 Given the high prevalence of hypertension, it follows that there are from 2 million to 4 million individuals with RAS in the United States alone. A challenging feature of the disease is the high incidence of adverse cardiovascular events in affected...
متن کاملTransient global amnesia following vertebral artery angioplasty and stenting.
temporal lobe, hippocampus or parahippocampal area is one possible cause [3] . Angioplasty with stenting of the posterior circulation is becoming a widely available neurointervention in patients with stenosis of the vertebral or basilar artery. We describe a patient with TGA following angioplasty with stenting of the vertebral artery. Dear Sir, Transient global amnesia (TGA) is a sudden-onset c...
متن کاملRenal artery rupture following cutting balloon angioplasty for fibromuscular dysplasia: a case report
INTRODUCTION Angioplasty with the use of cutting balloons has been suggested by some case reports and small series for the treatment of renal artery stenoses that are resistant to conventional balloon catheters. Based on this limited experience, the use of this technology has been suggested as safe. Herein, we report a renal artery rupture following angioplasty with a cutting balloon. The compl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the American College of Cardiology
سال: 2006
ISSN: 0735-1097
DOI: 10.1016/j.jacc.2006.04.025