Remote magnetic navigation–guided ventricular tachycardia ablation with continuous-flow mechanical circulatory support

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Advances in Mechanical Circulatory Support Bleeding and Thrombosis in Patients With Continuous-Flow Ventricular Assist Devices

Because of the obligate intravascular location of contemporary continuous-flow ventricular assist devices (CFVADs), it is not surprising that bleeding and thrombosis are among the most common and feared complications of this therapy, respectively. Although strides have been made in our understanding of the pathophysiology of continuous flow, intravascular CF-VADs have been widely used only in t...

متن کامل

Complications of Continuous-Flow Mechanical Circulatory Support Devices

Left ventricular assist devices (LVADs), more importantly the continuous-flow subclass, have revolutionized the medical field by improving New York Heart Association (NYHA) functional class status, quality of life, and survival rates in patients with advanced systolic heart failure. From the first pulsatile device to modern day continuous-flow devices, LVADs have continued to improve, but they ...

متن کامل

Characteristics of ventricular tachycardia ablation in patients with continuous flow left ventricular assist devices.

BACKGROUND Left ventricular assist devices (LVADs) are increasingly used as a bridge to cardiac transplantation or as destination therapy. Patients with LVADs are at high risk for ventricular arrhythmias. This study describes ventricular arrhythmia characteristics and ablation in patients implanted with a Heart Mate II device. METHODS AND RESULTS All patients with a Heart Mate II device who u...

متن کامل

Mechanical circulatory support for right ventricular failure.

OBJECTIVES The aim of this study was to explore the clinical utility of a commercially available centrifugal flow pump as a centrifugal flow-right ventricular support device (CF-RVSD) in patients with right ventricular failure (RVF). BACKGROUND RVF is associated with high in-hospital mortality. Limited data regarding efficacy of the CF-RVSD for RVF exist. METHODS We retrospectively reviewed...

متن کامل

Ablation of idiopathic left ventricular tachycardia using remote magnetic navigation integrated with advanced mapping.

1. García MJ, Lessick J, Hoffmann MH; CATSCAN Study Investigators. Accuracy of 16-row multidetector computed tomography for the assessment of coronary artery stenosis. JAMA. 2006;296:403-11. 2. Gaemperli O, Schepis T, Valenta I, Husmann L, Scheffel H, Duerst V, et al. Cardiac image fusion from stand-alone SPECT and CT: clinical experience. J Nucl Med. 2007;48:696-703. 3. Rubinshtein R, Gaspar T...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: HeartRhythm Case Reports

سال: 2019

ISSN: 2214-0271

DOI: 10.1016/j.hrcr.2019.01.002