منابع مشابه

Flow Injection System with Potentiometric Detection for the Determination of Urea Content in Milks

Two variant manifolds of a flow injection analysis (FIA) system are described for the determination of urea content in milks. This determination consists of the enzymatic reaction of urea with urease in which ammonium ion is formed. Ammonium is converted to ammonia by adding a NaOH solution and then led to a gas diffusion unit in which it diffuses to an acceptor channel (Tris/HCl, pH 7.5). Here...

متن کامل

Flow injection analysis of vancomycin

A flow injection method for the quantitative analysis of vancomycin hydrochloride, C66H75Cl2N9O24.HCl (HVCM), based on the reaction with copper (II) ions, is presented. HVCM forms a lilac-blue complex with copper ions at pH≅4.5 in aqueous solutions, with maximum absorption at 555 nm. The detection limit was estimated to be about 8.5×10-5 mol L-1; the quantitation limit is about 2.5×10-4 mol L-1...

متن کامل

Controlled dispersion analysis: flow-injection analysis without injection.

Flow-injection analysis is a precise, elegant, and economical technique, but its most troublesome feature is the mode of injection of the sample slug. We describe an alternative approach in which the sample is aspirated by the sample probe. In the simplest version the probe normally rests in reagent; when sampling is to take place, the pump is stopped and the probe is transferred to the sample ...

متن کامل

Detection of Abnormal Events via Optical Flow Feature Analysis

In this paper, a novel algorithm is proposed to detect abnormal events in video streams. The algorithm is based on the histogram of the optical flow orientation descriptor and the classification method. The details of the histogram of the optical flow orientation descriptor are illustrated for describing movement information of the global video frame or foreground frame. By combining one-class ...

متن کامل

Wall Shear Stress Calorimetric Micro-Sensor Designed for Flow Separation Detection and Active Flow Control

This paper presents an efficient and high-sensitive micro-sensor designed for wall shear stress measurement. The main technical application targeted is flow separation detection for closed-loop active flow control. The sensor is a temperature-resistance transducer operating on heat transfer. The device is micro-structured with three substrate-free wires presenting a high aspect ratio, and perio...