Reliability of ultrasonography measurement for the longus colli according to inward probe pressure

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reliability of ultrasonography measurement for the longus colli according to inward probe pressure.

[Purpose] To investigate the intra- and inter-rater reliability of the cross-sectional area (CSA) and muscle thickness (MT) of the longus colli according to the inward pressure of an ultrasonography (US) probe (0.5 and 1 kg). [Subjects] Thirteen subjects (11 males and 2 females; age, 23.1 ± 2.9 years) were recruited via convenience sampling of university students. [Methods] Real-time US measure...

متن کامل

Longus colli tendinitis.

A 44-year-old woman presented with a 4-day history of posterior neck pain with associated odynophagia. She denied any previous neck pain, trauma, or upper respiratory infections. Examination revealed bilateral posterior neck pain with decreased active and passive range of motion and tenderness with movement of the hyoid bone. Soft tissue neck radiograph revealed prevertebral soft tissue swellin...

متن کامل

Acute Calcific Tendonitis of the Longus Colli.

Background Acute calcific tendonitis of the longus colli (ACTLC) is an aseptic inflammatory response to deposition of calcium in the longus colli muscle tendons. Although reports in the literature are scarce, ACTLC likely represents an underreported disease process that routinely goes misdiagnosed. We report a case of ACTLC and provide a brief review of the literature. Case Report A 45-year-o...

متن کامل

Calcific tendinitis of the longus colli muscle.

Facility in the evaluation of the cervical prevertebral soft tissues should be a skill of any otolaryngologist. Tendinitis of the longus colli muscle mimics more serious disease processes of the prevertebral cervical region that the otolaryngologist may be required to evaluate. It has, however, received little attention in otolaryngological literature. Five cases from the Massachusetts Eye and ...

متن کامل

Design and Simulation of piezorestive pressure sensor for AFM Probe the displacement measurement

investigating pressure applied in surface vertically that is done by use of mechanical procedures isn’t efficient to measure pressure applied in inner surface of reservoir or pipes having gas due to entering pressure into whole walls and different surfaces. So, in order to measure this kind of pressure, several studies were conducted in past decades and also various procedures were proposed tha...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Physical Therapy Science

سال: 2015

ISSN: 0915-5287,2187-5626

DOI: 10.1589/jpts.27.3579