Reliability of the VmaxST Portable Metabolic Measurement System
نویسندگان
چکیده
منابع مشابه
Reliability and Validity of the VmaxST Portable Metabolic Analyzer
Background: The reliability and validity of the SensorMedics VmaxST was tested. Methods: Thirty subjects (age = 24.5 ± 4.0 years, height = 174.8 ± 9.8 cm, weight = 70.3 ± 12.6 kg) performed treadmill exercise on three occasions, twice using the VmaxST and once using the SensorMedics 2900 system. Oxygen consumption (VO2; L/min) and heart rate (HR; beats/min) were measured continuously during thr...
متن کاملAssessment of the aerosport TEEM 100 portable metabolic measurement system.
The present study evaluated the utility of a portable metabolic measurement system, the Aerosport TEEM 100. A total of 505 data points [242 from incremental (INC) and 263 from constant load (CL) exercise] were collected on 12 subjects (age = 25 +/- 4 yr), by placing the Aerosport TEEM 100 medium flow pneumotach and mouthpiece in-line with a validated system, the Rayfield system. When VO2 values...
متن کاملA Portable Stiffness Measurement System
A new stiffness measurement method is proposed that utilizes the lateral deformation profile of an object under indentation. The system consists of a force measurement module between a pair of equidistant touch sensing modules. Unique feature of the method is that by adjusting the touch module separation, indenter protrusion, and spring constant of the force sensing module, one can choose a des...
متن کاملعنوان روایی پایایی نسخه فارسی پرسشنامه سرمایه اجتماعی اونیکس در سالمندان validity and reliability of the persian version of onyx social capital measurement
مقدمه: یکی از چالشهایی که اغلب سالمندان با آن مواجهند برقراری ارتباط با افراد جدید و بزرگتر کردن دایره روابط اجتماعی خود می باشد. برقراری روابط اجتماعی و ایجاد و تقویت شبکه اجتماعی در سالمندان ممکن است منجر به ایجاد سرمایه اجتماعی شود. سرمایه اجتماعی یک مسئله چند بعدی است که ابعاد مختلفی از ساختار اجتماعی را در بر می گیرد. در این پژوهش بر آن بوده ایم که به تهیه نسخه فارسی پرسشنامه سرمایه اجتماع...
A portable insole plantar pressure measurement system.
To analyze plantar pressures during activities of daily living, one needs a fully portable system capable of measuring many steps over extended periods. This paper presents an inexpensive, reliable, portable plantar pressure acquisition system which we have developed. It allows the long-term recording (up to 2 hours) of pressure-time data from 14 pressure sensors within insoles. The sensor chos...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Sports Medicine
سال: 2008
ISSN: 0172-4622,1439-3964
DOI: 10.1055/s-2008-1038744