Reliability of international normalised ratios from two point of care test systems: comparison with conventional methods
نویسندگان
چکیده
منابع مشابه
Reliability of international normalised ratios from two point of care test systems: comparison with conventional methods.
OBJECTIVE To find out how accurately two point of care test systems--CoaguChek Mini and TAS PT-NC (RapidPointCoag)--display international normalised ratios (INRs). DESIGN Comparison of the INRs from the two systems with a "true" INR on a conventional manual test from the same sample of blood. SETTING 10 European Concerted Action on Anticoagulation centres. PARTICIPANTS 600 patients on lon...
متن کاملinvestigation of single-user and multi-user detection methods in mc-cdma systems and comparison of their performances
در این پایان نامه به بررسی روش های آشکارسازی در سیستم های mc-cdma می پردازیم. با توجه به ماهیت آشکارسازی در این سیستم ها، تکنیک های آشکارسازی را می توان به دو دسته ی اصلی تقسیم نمود: آشکارسازی سیگنال ارسالی یک کاربر مطلوب بدون در نظر گرفتن اطلاعاتی در مورد سایر کاربران تداخل کننده که از آن ها به عنوان آشکارساز های تک کاربره یاد می شود و همچنین آشکارسازی سیگنال ارسالی همه ی کاربران فعال موجود در...
on the comparison of keyword and semantic-context methods of learning new vocabulary meaning
the rationale behind the present study is that particular learning strategies produce more effective results when applied together. the present study tried to investigate the efficiency of the semantic-context strategy alone with a technique called, keyword method. to clarify the point, the current study seeked to find answer to the following question: are the keyword and semantic-context metho...
15 صفحه اولcomparison of the amount of debris extruded apically in two rotary techniques: flexmaster and m2
چکیده ندارد.
15 صفحه اولPoint-of-care International Normalised Ratios: UK NEQAS experience demonstrates necessity for proficiency testing of three different monitors.
External quality assessment (EQA) or proficiency testing is widely considered to be necessary for International Normalised Ratio (INR) determinations performed in conventional laboratory settings. There is increasing use of near-patient-test (NPT) or point-of-care (POC) INR devices and it is not known whether EQA is also necessary for these monitors. We report here on six years experience of pr...