Relaxation Property of Heat-Treated Prestressed-Concrete Steel Bar
نویسندگان
چکیده
منابع مشابه
Stress relaxation properties of prestressed steel wires
In this study, stress relaxation phenomenon has been examined generally. Experiments were carried out on carbon steel wires with diameter 8 mm which are particularly used in prestressed concrete composites. Thermomechanically heat treatment was also carried out on this wire in order to relieve the residual stresses accumulated after the cold work. The heat treatment temperature and the stretch ...
متن کاملFlexural Performance of High-strength Prestressed Concrete-encased Concrete-filled Steel Tube Sections
The sections composed of concrete and steel, which include concrete-encased concrete-filled tubes, generally have defects due to the low tensile strength of concrete. Therefore, an appropriate method was used for the combination of concrete-filled tubes (CFT) and prestressing strands which is encased in concrete. The conventional design guidelines are commonly developed for materials with norma...
متن کاملPrestressed Concrete Piles
A state of the art presentation on prestressed piling as used throughout the world is discussed in this General Report to the FIP Symposium on Mass-Produced Prestressed Precast Elements in Madrid, Spain, May 1968. Historical information, design data and notes along with manufacturing techniques, installation practices, discussion of problems and failures and a complete bibliography are all cove...
متن کاملAcoustic Inspection of Coated Steel Bar in Reinforced Concrete Structure
Bridges with reinforeerneut corrosion problems are now under careful inspection in Taiwan. Costly maintenance programs are underway and raising S"erious safety concem. There are various engineering solutions to salt-induced corrosion. Among them epoxycoated reinforcing bars, commonly referred to as rebar, are frequently used in marine environment and other areas due to its durability, reasonabl...
متن کاملDuctility of Prestressed and Partially Prestressed Concrete Beam Sections
D analyses of structures responding elastically to ground motions recorded during severe earthquakes have shown that the theoretical response inertia loads are generally significantly greater than the static design lateral loads recommended by codes. Hence, structures designed for the lateral earthquake loads recommended by codes can only survive severe earthquakes if they have sufficient ducti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: journal of the Japan Society for Testing Materials
سال: 1962
ISSN: 0372-7971
DOI: 10.2472/jsms1952.11.775