Relaxation Factor Optimization for Common Iterative Algorithms in Optical Computed Tomography
نویسندگان
چکیده
منابع مشابه
Iterative Algorithms in Tomography
The fundamental mathematical problem in tomographic image reconstruction is the solution, often approximate, of large systems of linear equations, which we denote here as Ax = b. The unknown entries of the vector x often represent intensity levels, of beam attenuation in transmission tomography, of radionuclide concentration in emission tomography, and so are naturally nonnegative. The entries ...
متن کاملLocal Diagnostic Reference Levels for Common Computed Tomography Procedures at a Tertiary Hospital in South Africa
Introduction: An operational computed tomography (CT) scanner is a major source of human exposure to ionizing radiation. Exposure increases the risk of cancer and aplastic anaemia. All radiation exposures should be justified and optimized to meet the clinical objective. In order to avoid the administration of excessive radiation dose to patients, diagnostic reference l...
متن کاملComputed Tomography Iterative Reconstruction Techniques.
For all their diagnostic value, computed tomography (CT) examinations have relatively high radiation exposure. Past efforts to decrease patient dose emphasized advances in data acquisition technology because attempts to decrease dose resulted in increased image noise from filtered back projection reconstruction techniques. Iterative reconstruction techniques lead to reduced dose and maintain im...
متن کاملComparing IDREAM as an Iterative Reconstruction Algorithm against In Filtered Back Projection in Computed Tomography
Introduction: Recent studies of Computed Tomography (CT) conducted on patient dose reduction have recommended using an iterative reconstruction algorithm and mA (mili-Ampere) dose modulation. The current study aimed to evaluate Iterative Dose Reduction Algorithm (IDREAM) as an iterative reconstruction algorithm. Material and Methods: Two CT p...
متن کاملDiagnostic Reference Level of Computed Tomography Examinations and Need for Dose Optimization in Ondo State, Nigeria
Introduction: The present study was conducted to obtain State diagnostic reference levels (DRLs) of five routine computed tomography (CT) examinations from two CT centers in Ondo State and to identify factors responsible for dose variation and escalation in these CT centers. Material and Methods: Acquisition parameters and CT dose indices wer...