Relative Frequency Calibration for Fast Frequency Sweep Microwave Reflectometry
نویسندگان
چکیده
منابع مشابه
Fast Frequency Sweep Technique for E cient
This paper describes a new approach to spectral response computation of an arbitrary 2D waveguide. This technique is based on the Tangential Vector Finite Element Method (TVFEM) in conjunction with the Asymptotic Waveform Evaluation (AWE) technique. The former is used to obtain modes characteristics for a central frequency, whereas the latter employs an eecient algorithm to compute frequency mo...
متن کاملDesign of a Microwave Frequency Sweep Interferometer for Plasma Density Measurements in Ecr Ion Sources∗
Electron Cyclotron Resonance Ion Sources (ECRIS) are among the candidates to support the growing request of intense beams of multicharged ions. Their further development is related to the availability of new diagnostic tools, nowadays consisting of few types only of devices designed on purpose for such compact machines. Microwave Interferometry is a non-invasive method for plasma diagnostics an...
متن کاملDigitally Range-Gated Optical Frequency Domain Reflectometry
Summary: We present a new optical frequency domain reflectometry technique which permits high frequency sweep repetition rates without sacrificing range. This technique could thus be adapted for remote and distributed acoustic sensing over long
متن کاملHigh fidelity imaging using frequency sweep encoding
Introduction: Recently Frydman et al proposed a novel mechanism for directly forming images in k space using frequency sweep encoding (1, 2). It relies on the quadratic dependence of magnetization phase on position. In combination with EPI-type readout, this method has found applications in single-shot spin-echo imaging of human and rat brains (3, 4). Its sequential excitation of magnetization ...
متن کاملSpatial frequency masking with the sweep-VEP
A suprathreshold sinewave grating can change the amplitude of the steady-state visual evoked potential (VEP) in response to a test grating if the two are close in spatial frequency (SF). The change in amplitude provides clues to underlying pattern analyzers. Masking was measured in 12 observers using the steady-state VEP. As a test grating reversed at 7 Hz, a masker of similar temporal frequenc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Plasma and Fusion Research
سال: 2007
ISSN: 1880-6821
DOI: 10.1585/pfr.2.040