Relationship among Corneal Biomechanics, Anterior Segment Parameters, and Geometric Corneal Parameters
نویسندگان
چکیده
منابع مشابه
Relationship among Corneal Biomechanics, Anterior Segment Parameters, and Geometric Corneal Parameters
Purpose. To investigate the relationship between corneal biomechanical parameters, anterior segment parameters, and geometric corneal parameters in a healthy Caucasian group. Methods. This retrospective study included the healthy eyes with best corrected visual acuity of at least 20/40 of 122 Caucasian subjects. The anterior segment parameters and geometric corneal parameters such as corneal vo...
متن کاملThe relationship between corneal biomechanics and anterior segment parameters in the early stage of orthokeratology
To investigate the relationship between corneal biomechanics and anterior segment parameters in the early stage of overnight orthokeratology.Twenty-three eyes from 23 subjects were involved in the study. Corneal biomechanics, including corneal hysteresis (CH) and corneal resistance factor (CRF), and parameters of the anterior segment, including corneal curvature, central corneal thickness (CCT)...
متن کاملTitle : the Variability of Corneal and Anterior Segment Parameters
30 Purpose: To analyse, describe and test diverse corneal and anterior segment parameters 31 in normal and keratoconic eyes to better understand the geometry of the keratoconic 32 cornea. 33 34 Method: 44 eyes from 44 keratoconic patients and 44 eyes from 44 healthy patients 35 were included in the study. The Pentacam System was used for the analysis of the 36 anterior segment parameters. New a...
متن کاملOcular anterior segment changes and corneal biomechanics in pregnancy.
Reply : We would like to apologize to Dr. Ali6 o if he was offended that his work was not cited in our review article. There was certainly no pur poseful intent on the part of the authors to exclude his work from our review nor to neglect his contribu tions to the field. Rather, our work was intended as a brief review of the existing technologies and, therefore, inevitably some concision was ...
متن کاملcomparison of corneal and anterior segment parameters between pentacam and galilei
baradaran rafii ar, md; motevasseli t, md*; yazdizadeh f, md; ansari sh, md; karimian f, md; sadoughi mm, md; kiani h ocular tissue engineering research center, shahid beheshti university of medical sciences, tehran, iran * corresponding author: [email protected] purpose: to compare anterior segment indices measured by two scheimpflug camera; galilei and pentacam. methods: in this observa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Ophthalmology
سال: 2016
ISSN: 2090-004X,2090-0058
DOI: 10.1155/2016/8418613