Relation between wire resistance and fluid pressure in the transient hot-wire method
نویسندگان
چکیده
منابع مشابه
Relation Between Wire Resistance and Fluid Pressure in the Transient Hot-Wire Method
The resistance of metals is a function of applied pressure, and this dependence is large enough to be significant in the calibration of transient hot-wire thermal conductivity instruments. We recommend that for the highest possible accuracy, the instrument's hot wires should be calibrated in situ. If this is not possible, we recommend that a value of γ, the relative resistance change with press...
متن کاملTransient thermal response of a hot-wire anemometer
The ability of a thermal anemometry system to accurately measure unsteady fluid velocity depends on the electrical control system as well as the thermal properties of the sensor. The present work is a numerical study of the thermal transient response of a hot-wire. A conventional constant temperature anemometer with an ideal feedback amplifier as well as a pulse width modulated system were used...
متن کاملAlgorithm to optimize transient hot-wire thermal property measurement.
The transient hot-wire method has been widely used to measure the thermal conductivity of fluids. The ideal working equation is based on the solution of the transient heat conduction equation for an infinite linear heat source assuming no natural convection or thermal end effects. In practice, the assumptions inherent in the model are only valid for a portion of the measurement time. In this st...
متن کاملEffect of Wire Pitch on Capacity of Single Staggered Wire and Tube Heat Exchanger Using Computational Fluid Dynamic Simulation
Single staggered is a design development of normal wire and tube heat exchanger that wires are welded with staggered configuration on two sides. Capacity of wire and tube heat exchanger is the ability of the heat exchanger to release heat. The objective of this study is to analyse the effect of wire pitch (pw) on capacity of single staggered wire and tube heat exchanger. The research...
متن کاملHot-wire anemometry for superfluid turbulent coflows.
We report the first evidence of an enhancement of the heat transfer from a heated wire to an external turbulent coflow of superfluid helium. We used a standard Pt-Rh hot-wire anemometer and overheat it up to 21 K in a pressurized liquid helium turbulent round jet at temperatures between 1.9 K and 2.12 K. The null-velocity response of the sensor can be satisfactorily modeled by the counterflow m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Research of the National Bureau of Standards
سال: 1989
ISSN: 0160-1741
DOI: 10.6028/jres.094.014