Reinforcement Schemes for Cold-Formed Steel Joists with a Large Web Opening in Flexural Zone - An Experimental Investigation
نویسندگان
چکیده
The objective of this investigation is to develop an economical and efficient reinforcement scheme for large web openings in cold-formed steel (CFS) joists flexural zones that would restore the original moment resistance section. This considered commonly used floor North American CFS construction. Tests on webs with no circular square located at mid-depth revealed may reduce strength by 23%. A consisting screw fastening 31.75 mm x 12.7 (1-1/2”x1/2”) bridging channels having matching thickness as receiving joist, along compression tensile edges opening utilizing a spacing was established. Three identical tests proposed restored corresponding strengths section under consideration, failure locations were outside reinforced regions.
منابع مشابه
Experimental Study for Strength Capacity of Cold-Formed Steel Joists Connections with Consideration of Various Bolts Arrangements
With growth the construction technologies, Cold-Formed Steel, CFS, sections are widely used in ordinary steel buildings because of some advantages such as light weight, ease of installation, decrease in cost, and increase in speed of operation. Using the bolted connections for CFS joist is one of the best details for steel structures. The main objective of this study is to conduct an experiment...
متن کاملShear Strength of Reinforced Web Openings in Steel Beams
The floor beams of steel buildings, cold-formed steel floor joists in particular, often require large web openings, which may affect their shear capacities. A cost effective way to mitigate the detrimental effects of such openings is to weld/fasten reinforcements. A difficulty associated with an experimental investigation to establish suitable reinforcement schemes for openings in shear zone is...
متن کاملExperimental Investigation on Cold-formed Steel Wall Plate System
A series of tests on cold-formed steel (CFS) wall plate system subjected to uplift force at the mid span of the wall plate is presented. The aim of the study was to study the behaviour and identify the modes of failure of CFS wall plate system. Two parameters were considered in these studies: 1) different dimension of U-bracket at the supports and 2) different sizes of lipped Cchannel. The lipp...
متن کاملExperimental Investigation on Cold-Formed Steel Foamed Concrete Composite Wall under Compression
A series of tests on cold-formed steel foamed concrete (CSFC) composite walls subjected to axial load were proposed. The primary purpose of the experiments was to study the mechanical behavior and identify the failure modes of CSFC composite walls. Two main factors were considered in this study: 1) specimen with pouring foamed concrete or without and 2) different foamed concrete density ranks (...
متن کاملOn Cold-Formed Steel Construction
Powder-actuated (also referred to as low velocity or powder-driven) fasteners are commonly used to attach cold-formed steel framing members, usually a track, to a concrete or structural steel support. Although commonly used, their behavior is less well understood than other fasteners such as screws, bolts and welds. The AISI Cold-Formed Steel Design Manual does not explicitly address powder act...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Canadian Journal of Civil Engineering
سال: 2021
ISSN: ['1208-6029', '0315-1468']
DOI: https://doi.org/10.1139/cjce-2021-0057