abstract: The increase in the use of flat slabs and need openings for passage installations, such as hydraulic electrical, which significantly reduces punching shear resistance capacity slab, makes understanding influence this type structure extremely necessary. structural behaviour with at different distances from column was investigated through five square (1,800 mm x 1,800 130 mm) supported on columns (150 150 tested until failure. results obtained experimentally were compared available literature, well responses predicted normative instructions. confirm high stresses concentration region between opening that situated 3d have no failure load slabs.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Structural Consideration in Design of Reinforced Concrete Slabs with Openings

Over 90% of framed structures in Uganda are built from reinforced concrete. Prior to the 1990’s, most buildings had no openings in slabs, yet in city centers buildings butt against each other with widows at front and back only. This limited retail activities to front rooms of the ground floor and the buildings had to be narrow. A baseline survey of 50 shopping malls in Kampala Central Business ...

متن کامل

Shear Capacity of Reinforced Concrete Flat Slabs Made with High-strength Concrete: A Numerical Study of the Effect of Size, Location, and Shape of the Opening (TECHNICAL NOTE)

Nowadays, concrete with strength higher than 50 MPa is utilized due to the ever increasing need for higher strength and prolonged healing properties. Despite the widespread use of high-strength concrete, only a few research projects have been conducted on the punching shear strength of high-strength concrete slabs. Reinforced concrete flat slabs are widely employed in structural systems. The lo...

متن کامل

Behaviour of fibre reinforced concrete slabs

This paper presents a comparison of the properties of concrete slabs when two types of fibres are added. One specimen had no fibres and acted as a control specimen. The remaining four specimens had steel and polypropylene fibres added in the volumetric ratio of 0.5% and 1.0%. The dimensions of the slab specimens were 820×820×80 mm and were supported by four rollers at their edges. A displacemen...

متن کامل

Assessment of Masonry Infilled Reinforced-concrete Frames with Openings

Original scientific paper Reinforced-concrete (R/C) frames infilled with masonry wall, especially with the presence of an opening, are insufficiently explored structural elements. We have experimentally investigated influence of the opening’s type and position to the lateral response of reinforced-concrete frames with masonry infill. Correction factors, that take into account influence of the o...

متن کامل

Experimental Strengthening of the Two-way Reinforced Concrete Slabs with High Performance Fiber Reinforced Cement Composites Prefabricated Sheets

Reinforced concrete structures need to be strengthened and retrofitted for various reasons, including errors during design and/or construction, so in most cases strengthening of structural elements is much more economical than rebuilding the structure. Using HPFRCC with tensile stiffening behavior has been developed to strengthen the concrete structures over the recent few years. In this paper,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Revista IBRACON de Estruturas e Materiais

سال: 2021

ISSN: ['1983-4195']

DOI: https://doi.org/10.1590/s1983-41952021000100011