Refuge alternatives relief valve testing and design with updated test stand
نویسندگان
چکیده
منابع مشابه
Refuge alternatives relief valve testing and design.
The U.S. National Institute for Occupational Safety and Health (NIOSH) has been researching refuge alternatives (RAs) since 2007. RAs typically have built-in pressure relief valves (PRVs) to prevent the unit from reaching unsafe pressures. The U.S. Mine Safety and Health Administration requires that these valves vent the chamber at a maximum pressure of 1.25 kPa (0.18 psi, 5.0 in. H2O), or as s...
متن کاملParallel and Sequential Testing of Design Alternatives
An important managerial problem in product design in the extent to which testing activities are carried out in parallel or in series. Parallel testing has the advantage of proceeding more rapidly than serial testing but does not take advantage of the potential for learning between tests, thus resulting in a larger number of tests. We model this trade-off in the form of a dynamic program and der...
متن کاملPressure Relief Valve Selection
Pressure relief valve is one of the most important devices used on the security of pipelines, since it is responsible to guarantee the integrity of the installations. Generally, the response and behavior of a relief valve during its transient is unknown by users, who employ simplified and static analysis to design the pipeline, further, the information provided by manufactures is limited. The f...
متن کاملAlternatives in animal testing.
1Division of Hematology/Oncology, Department of Medicine, Health Science Center, University of Florida, P.O. Box 100277, Gainesville, FL 32610, USA 2Division of Cardiology, Department of Medicine, Health Science Center, University of Florida, P.O. Box 100277, Gainesville, FL 32610, USA 3Department of Pathology, Health Science Center, University of Florida, P.O. Box 100277, Gainesville, FL 32610...
متن کاملA Test for Weibull IFR/DFR Alternatives Based on Type-2 with Replacement Censored Samples
This article presents a test based on quadratic form using Type-2 with replacement-censored sample for testing exponentiality against weibull IFR/DFR alternative. The percentile points and powers are simulated. The proposed test is compared with that of Bain and Engelhardt (1986) test. An example based on Type-2 censoring is also discussed.