Refractivities of the Inert Gases
نویسندگان
چکیده
منابع مشابه
The Uptake of Inert Gases in Diving
where Pabs is the absolute pressure and FtN2 is the fractional concentration of N2. If a diver, breathing 20% oxygen and 80% nitrogen, swims down to 30 MSW the inspired PN2 (PiN2) is calculated from equation 1 as: PiN2 = 4 bars x 0.8 = 3.2 bars. The lung alveolar PN2 (PAN2) will be slightly lower than this, but for the sake of simplicity we will assume that it also is 3.2 bars. The venous blood...
متن کاملNarcosis and Emulsion Reversal by Inert Gases
Investigations of the effect of high pressures of Na (100 to 130 atmospheres) and of Ar (60 to 80 atmospheres) showed that these gases are effective in reversing the phases of an oil in water emulsion. Nitrous oxide did not cause reversal at pressures as high as 53 atmospheres nor did helium as high as 107 atmospheres. We found CO(2) most effective in reversing the emulsions and attributed this...
متن کاملAnharmonicity and potentials for the solidified inert gases
The parameters for a representative two-body Morse potential are determined for the solidified inert gases by fitting to O'K solid data. This is done using first the harmonic approximation and subsequently the first-order self-consistent harmonic approximation, which provides an upper limit to the anharmonic correction, to describe the solid at O'K. On comparing the two cases, the effect on the...
متن کاملImaging obstructed ventilation with NMR using inert fluorinated gases.
We partially obstructed the left bronchi of rats and imaged an inert insoluble gas, SF(6), in the lungs with NMR using a technique that clearly differentiates obstructed and normal ventilation. When the inhaled fraction of O(2) is high, SF(6) concentrates dramatically in regions of the lung with low ventilation-to-perfusion ratios (VA/Q); therefore, these regions are brighter in an image than w...
متن کاملLimitation of the use of inert gases in the measurement of small gut mucosal blood flow.
The role of blood flow in absorption from the small gut would be best studied by a method able to measure exclusively blood flow in the small gut mucosa because this might vary independently of total small gut blood flow. Such a method should be repeatable to give values in control and experimental periods, and one would hope that it would be adaptable for use in man. We had hoped to meet these...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nature
سال: 1902
ISSN: 0028-0836,1476-4687
DOI: 10.1038/066607b0