Referenceless interleaved echo‐planar imaging
نویسندگان
چکیده
منابع مشابه
Referenceless interleaved echo-planar imaging.
Interleaved echo-planar imaging (EPI) is an ultrafast imaging technique important for applications that require high time resolution or short total acquisition times. Unfortunately, EPI is prone to significant ghosting artifacts, resulting primarily from system time delays that cause data matrix misregistration. In this work, it is shown mathematically and experimentally that system time delays...
متن کاملEchoplanar chemical shift imaging.
A novel method of chemical shift imaging utilizing echoplanar imaging (EPI) has been developed for the purpose of improving the spatial resolution of metabolite images for the specific goal of high spatial resolution mapping of neuronal content. An EPI sequence was modified to allow temporal offsets of the 180 degree refocusing pulse that encode the chemical shift information into the phase of ...
متن کاملApplications of high-resolution echoplanar spectroscopic imaging for structural imaging.
Echoplanar spectroscopic imaging (EPSI) was introduced as a fast alternative for spectroscopic imaging and has been recently implemented on clinical scanners. With further advances in gradient hardware and processing strategies, EPSI can be used to obtain spectroscopic images whose spatial resolution parallels that of conventional anatomic images within clinically acceptable acquisition time. T...
متن کاملPulsed interleaved excitation fluctuation imaging.
Fluorescence fluctuation imaging is a powerful means to investigate dynamics, interactions, and stoichiometry of proteins inside living cells. Pulsed interleaved excitation (PIE) is the method of nanosecond alternating excitation with time-resolved detection and allows accurate, independent, and quasi-simultaneous determination of fluorescence intensities and lifetimes of different fluorophores...
متن کاملReferenceless PRF shift thermometry.
The proton resonance frequency (PRF) shift provides a means of measuring temperature changes during minimally invasive thermotherapy. However, conventional PRF thermometry relies on the subtraction of baseline images, which makes it sensitive to tissue motion and frequency drift during the course of treatment. In this study, a new method is presented that eliminates these problems by estimating...