Reference ranges for two-dimensional echocardiographic examination of the fetal ductus arteriosus

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contrast echocardiographic assessment of the neonatal ductus arteriosus.

Contrast echocardiography is a safe and accurate method of diagnosing patent ductus arteriosus (PDA) in newborn infants. In this study the presence of PDA in very low birthweight infants receiving mechanical ventilation was investigated by contrast echocardiography. This was used as a basis for determining the accuracy of clinical signs and M mode echocardiography in the diagnosis of PDA. At th...

متن کامل

Echocardiographic assessment of ductus arteriosus shunt in premature infants.

Echocardiograms were performed on premature infants with a patent ductus arteriosus (PDA) in order to assess the magnitude of the left-to-right shunt. Ten of 14 infants with a hemodynamically significant PDA required ligation because of intractable cardiac failure. Twenty infants served as controls. These consisted of seven infants without heart disease, ten infants who were examined echocardio...

متن کامل

Echocardiographic parameters of patent ductus arteriosus in preterm infants.

OBJECTIVE To analyze cardiovascular parameters by echocardiography in preterm infants with patent ductus arteriosus (PDA). SETTING Tertiary-care pediatric university hospital. DESIGN Cross-sectional, hospital-based study. PARTICIPANTS 58 preterm infants, gestational age less than 33 weeks. MEASUREMENTS A complete 2-dimension, M-mode, color doppler echocardiography was performed in each ...

متن کامل

Echocardiographic Evaluation of Patent Ductus Arteriosus in Preterm Infants

Patent ductus arteriosus (PDA) is part of the typical morbidity profile of the preterm infant, with a high incidence of 80-90% in extremely low birth weight infants born before 26 weeks of gestation. Whereas spontaneous closure of the ductus arteriosus (DA) is likely in term infants, it is less so in preterm ones. PDA is associated with increased mortality and various comorbidities including ca...

متن کامل

Echocardiographic reference ranges for sedentary donkeys in the UK.

The aim of this study was to provide two-dimensional (2D) and M-mode echocardiographic reference ranges from a sample of the UK population of donkeys including geriatrics (>30 years), owned by The Donkey Sanctuary, and to assess the influence of gender, weight and age on these variables. A total of 36 donkeys with no clinical or echocardiographic evidence of cardiovascular disease were examined...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Ultrasound in Obstetrics and Gynecology

سال: 2000

ISSN: 0960-7692

DOI: 10.1046/j.1469-0705.2000.00078.x