Reduction methods for nonlinear steady-state thermal analysis
نویسندگان
چکیده
منابع مشابه
Steady State Analysis of Nanofuel Droplet Evaporation
The potential for nanofuels as one of the clean sources of energy on account of its enhanced combustion performance coupled with low emissions has been established. Considering the importance of the fuel evaporation phase in the entire combustion process, this work presents an attempt at applying the steady state analysis equations to nanofuel experimental data obtained from the li...
متن کاملSteady-state perturbative theory for nonlinear circuits
We study the steady-state behavior of a damped, driven nonlinear LRC oscillator, where the nonlinearity arises due to voltage-dependent capacitance. The driving or input signal is assumed to be a pure tone. Using an iterative, perturbative solution technique combinedwith an energy conservation argument, we show that the oscillator transfers energy from the fundamental to higher harmonics. We de...
متن کاملStochastic Galerkin Methods for the Steady - State
We study the steady-state Navier-Stokes equations in the context of stochastic finite element discretizations. Specifically, we assume that the viscosity is a random field given in the form of a generalized polynomial chaos expansion. For the resulting stochastic problem, we formulate the model and linearization schemes using Picard and Newton iterations in the framework of the stochastic Galer...
متن کاملSteady - state MRI : methods for neuroimaging REVIEW
MRI pulse sequences that use regularly spaced trains of rapidly applied excitation pulses (every few milliseconds) are known as ‘steady-state’ sequences. Under these conditions, the magnetization evolves into a steady state that depends on tissue parameters such as T1, T2 and diffusion, as well as sequence parameters such as repetition time and flip angle. These sequences have attractive proper...
متن کاملNovel Methods for Steady-state Neuroimaging
Magnetic Resonance Imaging (MRI) has had a major impact on neuroscience due to the flexibility of MRI contrast. In particular, functional MRI (FMRI) and diffusionweighted imaging (DWI) have provided neuroscientists with unique and powerful methods for studying brain function and structure. However, neither of these methods has the signal-to-noise ratio (SNR), spatial resolution or image quality...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal for Numerical Methods in Engineering
سال: 1984
ISSN: 0029-5981,1097-0207
DOI: 10.1002/nme.1620200711