Reduced field of view and undersampled PR combined for interventional imaging of a fully dynamic field of view

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reduced circular field-of-view imaging.

A rapid dynamic imaging technique based on polar k-space sampling is presented. A gain in temporal resolution is achieved by angular undersampling. A detailed analysis of the point spread function of angular undersampled polar imaging reveals a reduced diameter of the corresponding circular field of view. Under the assumption that dynamic changes are restricted to a local circular field of view...

متن کامل

fabrication of new ion sensitive field effect transistors (isfet) based on modification of junction-fet for analysis of hydronium, potassium and hydrazinium ions

a novel and ultra low cost isfet electrode and measurement system was designed for isfet application and detection of hydronium, hydrazinium and potassium ions. also, a measuring setup containing appropriate circuits, suitable analyzer (advantech board), de noise reduction elements, cooling system and pc was used for controlling the isfet electrode and various characteristic measurements. the t...

diagnostic and developmental potentials of dynamic assessment for writing skill

این پایان نامه بدنبال بررسی کاربرد ارزیابی مستمر در یک محیط یادگیری زبان دوم از طریق طرح چهار سوال تحقیق زیر بود: (1) درک توانایی های فراگیران زمانیکه که از طریق برآورد عملکرد مستقل آنها امکان پذیر نباشد اما در طول جلسات ارزیابی مستمر مشخص شوند; (2) امکان تقویت توانایی های فراگیران از طریق ارزیابی مستمر; (3) سودمندی ارزیابی مستمر در هدایت آموزش فردی به سمتی که به منطقه ی تقریبی رشد افراد حساس ا...

15 صفحه اول

simulation and experimental studies for prediction mineral scale formation in oil field during mixing of injection and formation water

abstract: mineral scaling in oil and gas production equipment is one of the most important problem that occurs while water injection and it has been recognized to be a major operational problem. the incompatibility between injected and formation waters may result in inorganic scale precipitation in the equipment and reservoir and then reduction of oil production rate and water injection rate. ...

3D Submillimeter-Resolution Reduced-Field-of-View Diffusion Tensor Imaging

Introduction For better delineation of neuronal architecture, higher spatial resolution is always desirable. Challenges in realization of high spatial resolution include but are not limited to long total scan time, low signal-to-noise ratio (SNR), and high sensitivity to T2* blurring, off-resonance, and motion-related artifacts. In the present work, the reduced field-of-view (rFOV) imaging appr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Magnetic Resonance in Medicine

سال: 2004

ISSN: 0740-3194,1522-2594

DOI: 10.1002/mrm.20037