FDG-PET/CT for driveline infection in a patient with implantable left ventricular assist device.
can Society of Echocardiography Council for Intraoperative Echocardiography and the Society of Cardiovascular Anesthesiologists Task Force for Certification in Perioperative Transesophageal Echocardiography. J Am Soc Echocardiogr 1999;12: 884–900. 21. Wong DT, Bertaso AG, Liew GY, Thomson VS, Cunnington MS, Richardson JD et al. Relationship of aortic annular eccentricity and paravalvular regurg...
متن کاملLeft ventricular assist device driveline infection and the frequency of dressing change in hospitalized patients.
OBJECTIVES To determine if driveline infection is related to dressing change frequency in hospitalized adult patients with newly implanted left ventricular assist devices (LVAD). BACKGROUND Guidelines do not exist for the frequency of driveline exit-site dressing change in hospitalized patients resulting in wide variation in practice. METHODS A retrospective chart review was conducted on 68...
متن کاملLate driveline left ventricular assist device infection treated with frozen-and-thawed allogeneic platelet gel.
In this case report, we report the application of frozen-and-thawed allogeneic platelet gel (PLT-gel) to treat a late driveline exit site infection in a 56-year old patient supported by a Heartware-HVAD left ventricular assist device. The treatment duration was 4 weeks and at the follow-up the skin around the exit site was free from further infection. PLT-gel can be used to treat local infectio...
متن کاملDesign an Equivalent Left Ventricular Assist Device for Medical Equipment Labs
LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...
متن کاملImprovement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization
In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...