Rectangular current pulse generator to test varistors with pulsed electrical load

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Parametric Analyses on Rectangular Pulse Current Generator for Virtual High Voltage Laboratory Environment

ABSTRACT This paper presents the development work done for virtualization of a typical high voltage laboratory especially named as virtual high voltage laboratory. The main objective of the paper is to develop an understanding of rectangular pulse current generator’s circuit parameters’ effect on the standard output waveforms. The most significant part includes analyses of various internal cons...

متن کامل

Fast, high-current pulse generator with variable amplitude and width

a one-dimensional random walk, for which the statistical properties are well known. The essential idea behind this approach can best be seen in Eq. (2) where the individual t; + r terms in the sum on the left represent steps in a unidirectional random walk, the walk being terminated when the value Tis reached. A detailed treatment (facilitated by the definition of the I; given above) shows that...

متن کامل

Defect edge identification with rectangular pulsed eddy current sensor based on transient response signals

The Pulsed Eddy Current (PEC) testing is an increasingly emerging nondestructive testing & evaluation (NDT&E) technique. The main purpose of this study is to improve the performance of defect edge identification of C-scan imaging technique utilizing the rectangular PEC sensor. When sensor scans along the defect, peak waves of response signals always present a crest and a trough in direction of ...

متن کامل

The pLAB Picturebook: Load Test For the SG100 Security Generator

This report gives the empirical results of the SG100 Security Generator in the Load Test.

متن کامل

A Novel 36-pulse rectifier with low kVA rate to reduce harmonic input current distortion

The increase in the number of pulses in multipulse rectifiers leads to a reduction in harmonic current distortion. But this increase in the number of pulses leads to an increase in kVA, cost, and complexity of the multi-pulse rectifiers. As a result, in industrial applications, 12-pulse rectifiers are mainly used due to their lightweight, simple transformers, and low kVA rate, and low cost. The...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IOP Conference Series: Materials Science and Engineering

سال: 2021

ISSN: 1757-8981,1757-899X

DOI: 10.1088/1757-899x/1089/1/012018