منابع مشابه
Improving the workability and strength of silica fume concrete by using silane-treated silica fume
Mortar with high workability even without a water-reducing agent and with high tensile and compressive strengths (3.1 and 78 MPa, respectively) was obtained by using as an admixture silica fume that had been surface treated with a silane coupling agent. The treatment enhanced the wettability of silica fume by water, thereby increasing the workability of the mortar mix. It also enhanced the bond...
متن کاملEffects of Silica Fume in Conventional Concrete
The production of tailor made high strength and high performance concrete are made by incorporating silica fume into the normal concrete and it is a routine one in the present days. The mix proportioning is intricate and the design parameters are increased due to the incorporation of silica fume in conventional concrete. The aim of this paper is to look into the different mechanical properties ...
متن کاملInfluence of Silica Fume on Normal Concrete
The incorporation of silica fume into the normal concrete is a routine one in the present days to produce the tailor made high strength and high performance concrete. The design parameters are increasing with the incorporation of silica fume in conventional concrete and the mix proportioning is becoming complex. The main objective of this paper has been made to investigate the different mechani...
متن کاملInfluence of Nano-Silica and Silica Fume in the Steel Corrosion Embedded in Concrete
Corrosion of steel is one of the most important potential dangers and threats in concrete structures. Corrosion of steel embedded in reinforced concrete plays a key role in reducing the strength and durability of reinforced concrete. Several studies have proposed that alternative approaches to enhancing the performance of reinforced concrete and its resistance to corrosion. In this study, the r...
متن کاملInfluence of Silica Fume on Chloride Resistance of Concrete
A series of concrete slabs were cast with 0, 7, and 12% by mass silica fume replacement of cement at W/CM = 0.35, 0.40, and 0.45. After either moist or steam curing, a variety of chloride resistance tests were performed. These included AASHTO T259, modified T259, T277, as well as several bulk diffusion tests and sorptivity tests. Results indicate that the use of properly dispersed silica fume r...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Non-Crystalline Solids
سال: 2011
ISSN: 0022-3093
DOI: 10.1016/j.jnoncrysol.2010.09.079